Electrical Application Details for App #: B434866
Premises: 805 ST MARKS AVENUE BROOKLYN BIN: 3341622     Block: 1221   Lot: 53
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 805 ST MARKS AV Census Tract:   313 Health Area:  2900
C5-E C2-I D5-I Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11213 Community Board:   308
DOB Cross Street(s):   NEW YORK AVENUE,    BROOKLYN AVENUE
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  09/26/2017 9:00 AM
Application Entered:   09/26/2017 Job Start Date:   10/01/2017
Last Change:   08/22/2025 Job End Date:   12/30/2017
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   JOHN, CHARLES       On     10/27/2018      
Field Disp:   V - OBJCTN ISSD: JOB INCOMPLT
Energize Recommendation:  
Objection Disposition:  

License #: 012702 Licensee Name: ALLAN TANG
Firm: 004539 Firm Name: A ELECTRICAL MAIN SVC INC
Firm Phone: 718-234-9250  Firm Address: 198 AVENUE S, 1ST FLOOR BROOKLYN NY 11223 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $120.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: CHOTHI KUNAL
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  3  20-CIRCUIT
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
002  C2-I    20  19             
005  C5-E    20  19             
005  D5-I    20  19             
Buildings Total   60  12  24  57                
Total Units : 153 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: V - OBJECTION(S) EXIST
Power Requested: Notice: 1 - FIRST NOTICE 10/29/2018
Power Issued: Response:  

Follow-Up:
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B434866
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/27/2018 10/29/2018 CJH V (35) (7)
INSPECTION COMMENTS: NO ACCESS TO C5E, D5I

OBJECTION FOR APPLICATION #: B434866
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(FLOOR: 002) APT C2I ONE CKT PROVIDED FOR KITCHEN C-TOP 210.52
OPEN 10/27/2018 10/27/2018
 
002 (999) OTHER
(FLOOR: 002)APT C2I KITCHEN C-TOP GFCI SHARE WITH LUMINAIRES 210.52 B2
OPEN 10/27/2018 10/27/2018
 
003 (999) OTHER
(FLOOR: 002) APT C2I PNL KO MISSING 110.12
OPEN 10/27/2018 10/27/2018
 
004 (999) OTHER
(FLOOR: 002) APT C2I BATH ROOM LUMINAIRES NOT SUITABLE 410.10
OPEN 10/27/2018 10/27/2018
 
005 (999) OTHER
(FLOOR: 002) APT C2I RECEPT OUTLETS NOT GROUNDED 250.146
OPEN 10/27/2018 10/27/2018
 
006 (999) OTHER
(FLOOR: 002) APT C2I LIVING ROOM NOT AFCI PROTECTED 210.12B
OPEN 10/27/2018 10/27/2018
 
007 (999) OTHER
(FLOOR: 002) APT C2I RECEPT OUTLETS SHEET ROCK SCREWS IN USED 250.8
OPEN 10/27/2018 10/27/2018