BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B432887
Premises: 391 14 STREET BROOKLYN BIN: 3026512     Block: 1100   Lot: 72
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 391 14 ST Census Tract:   149 Health Area:  4700
BAS,1,2,3,4 FLOORS Admin Area:   B - BROOKLYN Inspection Area:   F
BROOKLYN, NY 11215 Community Board:   306
Related Job Number:    310139105
DOB Cross Street(s):    7 AVENUE,    8 AVENUE
Status:   C - JOB IS SIGNED OFF 06/28/2019
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/14/2017 9:13 PM
Application Entered:   08/14/2017 Job Start Date:   08/15/2017
Last Change:   06/28/2019 Job End Date:   12/30/2017
Appointment Status:   
Last Inspection By:   NAJI PHILLIIPS       On     06/28/2019      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 010587 Licensee Name: HARRY FRENKEL
Firm: 002697 Firm Name: APOLLO ELECTRIC INC.
Firm Phone: 212-627-2561  Firm Address: 127 WEST 24TH ST,5TH FL STE#A NEW YORK NY 10011 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $578.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JOHN SAIA
Owner Business Name: 391 14 SRT REALTY LLC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  9  100A
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  400A
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  9  3/3
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  9  20CRT
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS                 
001  15           
001  15           
002  10  16           
002  10  16           
003  15           
003  16           
004  10  15           
004  19  15    10         
Buildings Total 88  129    63  70     24           
Total Units : 374 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 9 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 9 - Removed Meters 0 = Total Meters 9

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 08/14/2017 Notice: 1 - FIRST NOTICE 06/17/2019
Power Issued: 08/14/2017 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B432887
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/14/2019 06/17/2019 NJP V (45) (5)
INSPECTION COMMENTS: CORRECT OBJECTIONS.
 
(2) 06/28/2019 06/28/2019 NJP C R (40) (0)
INSPECTION COMMENTS: OBJECTIONS RESOLVED

OBJECTION FOR APPLICATION #: B432887
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(ALL FLOORS)MICROWAVE RECEP OUTLET BOX INSTALLED IN COMBUSTIBLE MATERIAL. (ART314.20)
RSLV 06/14/2019 06/14/2019 06/28/2019
 
002 ( 17) DEFECTIVE SWITCHES ARE IN USE
(CELLAR) PLP MAIN BREAKER DOES NOT SIMULTANEOUSLY TRIP (ART 210.4B)
RSLV 06/14/2019 06/14/2019 06/28/2019
 
003 (279) WATER METER JUMPER IS MISSING/IMPROPER
(CELLAR) WATER METER JUMPER WAS NOT PROVIDED (ART 250. 53)
RSLV 06/14/2019 06/14/2019 06/28/2019
 
004 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
(CELLAR)SVC PLP PANEL HAS NOT BEEN PROVIDED WITH A PANEL DIRECTORY (ART408.4)
RSLV 06/14/2019 06/14/2019 06/28/2019
 
005 (999) OTHER
(GROUND FLOOR) BACK APT DISHWASHER ARMORED CABLE NOT TERMINATED.
RSLV 06/14/2019 06/14/2019 06/28/2019



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order