Electrical Application Details for App #: B430721
Premises: 456 SACKETT STREET BROOKLYN BIN: 3007139     Block: 430   Lot: 21
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 456 SACKETT ST Census Tract:   75 Health Area:  2500
BASEMENT, 1ST, 2ND Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11231 Community Board:   306
Related Job Number:    321186024
DOB Cross Street(s):   HOYT STREET,    BOND STREET
Status:   C - JOB IS SIGNED OFF 08/30/2018
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  06/27/2017 8:01 PM
Application Entered:   06/27/2017 Job Start Date:   06/27/2017
Last Change:   08/30/2018 Job End Date:   06/27/2018
Appointment Status:   
Last Inspection By:   NAJI PHILLIIPS       On     08/29/2018      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012324 Licensee Name: GERBERT BONHOMME
Firm: 004105 Firm Name: SUPREME ELECTRIC CORP
Firm Phone: 718-658-1078  Firm Address: 107-54 SUTPHIN BLVD JAMAICA NY 11435 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
7 - HVAC WIRING
L - LIGHTING WORK
Total Fee:  $115.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   Yes
Job Number:  321186024
Building Used As:   A - One Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: ERAN MALKA
Owner Business Name: 456 SACKETT STREET LLC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  30A DISCONNECT
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  2  20/20 W/ MAIN
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS    10  20    10             
001    16  20    16         
002    16  20    16         
Buildings Total 42  60    14  42              
Total Units : 160 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 1 + New Meters 1 - Removed Meters 1 = Total Meters 1

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 06/27/2017 Notice: 1 - FIRST NOTICE 08/24/2018
Power Issued: 06/27/2017 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B430721
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 08/24/2018 08/24/2018 NJP V (75) (7)
INSPECTION COMMENTS: CORRECT OBJECTIONS.
 
(2) 08/29/2018 08/30/2018 NJP C R (38) (0)
INSPECTION COMMENTS: OBJECTIONS RESOLVED.

OBJECTION FOR APPLICATION #: B430721
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(ALL FLOORS)BATHROOM/KITCHEN OUTLET BOX SETBACK IS MORE THAN 1/4" IN WALL. (ART314.20)
RSLV 08/24/2018 08/24/2018 08/29/2018
 
002 (999) OTHER
(ALL FLOORS) CLOSET LIGHTS NOT SUITABLE FOR LOCATION.
RSLV 08/24/2018 08/24/2018 08/29/2018
 
003 ( 24) ARMORED CABLES ARE NOT PROPERLY SECURED
(BASEMENT)MECHANICAL ARMORED CABLE IS NOT PROPERLY SECURED (ART 320.30)
RSLV 08/24/2018 08/24/2018 08/29/2018
 
004 (279) WATER METER JUMPER IS MISSING/IMPROPER
(BASEMENT) WATER METER JUMPER IS MISSING (ART 250.53)
RSLV 08/24/2018 08/24/2018 08/29/2018
 
005 (145) APPLIANCE DISCONNECT NOT PROVIDED/IDENTIFIED.
(ROOF) HVAC UNIT NOT PROPERLY IDENITIFIED (ART 422.30)
RSLV 08/24/2018 08/24/2018 08/29/2018
 
006 (999) OTHER
(ROOF) HVAC UNIT THERMOSTAT SPLICED IN HVAC DISCONNECT (ART 725)
RSLV 08/24/2018 08/24/2018 08/29/2018
 
007 (999) OTHER
(ROOF) HVAC SERVICE OUTLET NOT ACCESSIBLE.
RSLV 08/24/2018 08/24/2018 08/29/2018