| NYC Department of Buildings | ||
| Electrical Application Details for App #: B424545 | ||
| Premises: 208 42 STREET BROOKLYN | BIN: 3010782 Block: 722 Lot: 11 |
| Printable (PDF) version of this Permit | |||||||||||
| DOB NOW: Inspections | |||||||||||
| Filed: | 208 42 ST | Census Tract: 2 | Health Area: 4400 | |
| BUILDING | Admin Area: B - BROOKLYN | Inspection Area: F | ||
| BROOKLYN, NY 11232 | Community Board: 307 | |||
| DOB Cross Street(s): 2 AVENUE, 3 AVENUE | |||
| Status: E - ABANDONED 08/22/2025 | |||
| Request Type: A - APPLICATION | eFiled: YES | Permit Issued: 02/23/2017 7:01 PM | |
| Application Entered: 02/23/2017 | Job Start Date: 02/23/2017 | ||
| Last Change: 08/22/2025 | Job End Date: 02/22/2018 | ||
| COMPLETION FEE WAS BILLED | |||
| Appointment Status: | |||
| Last Inspection By: On | |||
| Field Disp: | |||
| Energize Recommendation: | |||
| Objection Disposition: | |||
| License #: | 011762 | Licensee Name: | RABINDRA N RAMGARIB | |
| Firm: | 003374 | Firm Name: | INDY ELECTRIC CORP. | |
| Firm Phone: | 718-323-4639 | Firm Address: | 120-21 101 AVENUE RICHMOND HILL NY 11419 | |
| Work Started or Filed by Others: NO | ||||||||
| Work Category: R - REHABILITATION | Work To Be Done:
1 - SERVICE WORK/NOTIFY UTILITY 6 - GENERAL WIRING |
Total Fee: $191.00 | ||||||
| Other Work: | ||||||||
| Work Related to a New or Amended Certificate of Occupancy: NO | ||||||||
| This Job Regulated by the NYC Energy Conservation Code: No | ||||||||
| Building Used As: Z - Commercial/Residential (1 Stores, 2 Apartments) | |||||||
| Special Cert Approval: | |||||||
| Advisory Board Approval: NOT APPLICABLE | |||||||
| Owner / Occup: | TURAG KOKHABI | ||||||
| Owner Business Name: | 42 BROOKLYN, INC | ||||||
| Authorized Representative: | |||||||
| Relationship To Owner: | |||||||
|
|
| Floor | Apt. | Number Of Outlets | No. Of Fixtures |
Motors / Generators | Heaters | Transformers | ||||||
| Fixt | Receptacles | Switch | Num | Total HP KW | Num | Total KW | Num | Total KVA | ||||
| ATT | A/C | |||||||||||
| BAS | 6 | 10 | 4 | 6 | ||||||||
| GND | 6 | 15 | 1 | 3 | 6 | |||||||
| 001 | 8 | 20 | 2 | 6 | 8 | |||||||
| 002 | 8 | 30 | 3 | 8 | 8 | |||||||
| Buildings Total | 28 | 75 | 6 | 21 | 28 | |||||||
| Total Units : 158 units | ||||||||||||
| Signs: | Field Connect: | 0 | Field Inspect: | 0 | Tags: | ||
| Meter Request to Utility | #3-Wire | 1 | #4-Wire | 0 | #10-Wire | 0 | |
| Existing Meters | 2 | + New Meters | 3 | - Removed Meters | 2 | = Total Meters | 3 |
| Power Auth Flag: | I - ISSUED | Objection Flag: | |
| Power Requested: | 02/23/2017 | Notice: | |
| Power Issued: | 02/23/2017 | Response: |
| Follow-Up: | |||
| Contractor's Comments: NEW ELECTRICAL SERVICE. NEW BUILDING WIRING. | |||
|
|
| *NO INSPECTION RECORDS FOUND FOR ELECTRICAL APPLICATION NUMBER B424545 |