Electrical Application Details for App #: B418468
Premises: 420 KENT AVENUE BROOKLYN BIN: 3425676     Block: 2134   Lot: 56
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 420 KENT AV Census Tract:   547 Health Area:  0500
WHOLE BUILDING Admin Area:   B - BROOKLYN Inspection Area:   B
BROOKLYN, NY 11249 Community Board:   301
DOB Cross Street(s):   SOUTH 8 STREET,    SOUTH 9 STREET
Status:   C - JOB IS SIGNED OFF 08/24/2020
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  10/10/2016 3:53 PM
Application Entered:   10/10/2016 Job Start Date:   10/11/2016
Last Change:   08/24/2020 Job End Date:   10/11/2019
Appointment Status:   
Last Inspection By:   CAMPBELL, C       On     08/22/2020      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 011334 Licensee Name: MICHAEL KATZ
Firm: 002750 Firm Name: A & M ELEC'L SERVICE INC.
Firm Phone: 718-668-1908  Firm Address: 516 INDUSTRIAL LOOP S.I NY 10309 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
T - TEMPORARY LIGHT & POWER
Total Fee:  $2,702.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: 420 KENT AV
Authorized Representative:  CHARLWS MORISI
Relationship To Owner:   MANAGER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  2  600 AMP
D. 601 Up to 1200 AMPS  1  800 AMP
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  12  #2
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  4  500 MCM, 300 MCM
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  12  
D. 3 Phase Over 225 AMPS  4  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL    100  50      100             
001    100  50      100             
002    80  40      80             
003    80  40      80             
004    50  25      50             
005    50  25      50             
006    50  25      50             
007    50  25      50             
008    50  25      50             
009    50  25      50             
010    50  25      50             
011    50  25      50             
012    50  25      50             
013    50  25      50             
014    50  25      50             
015    50  25      50             
016    50  25      50             
017    50  25      50             
018    50  25      50             
019    50  25      50             
020    50  25      50             
021    50  25      50             
022    50  25      50             
ROF    50  25      50             
Buildings Total 1360  680      1360                
Total Units : 3400 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 1
Existing Meters 0 + New Meters 1 - Removed Meters 0 = Total Meters 1

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 10/10/2016 Notice:  
Power Issued: 10/10/2016 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  TEMPORARY LIGHT AND POWER. POWER TO THE HOIST. POWER TO THECRANE

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B418468
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 08/22/2020 08/24/2020 CLC C (30) (0) Y
INSPECTION COMMENTS: ALL TEMP WIRING REMOVED