| BUILDING OVERVIEW |
Are Feeders Being Installed? : No |
| (If feeders are being installed, provide a wiring diagram and calculations at the time of inspection) |
| Building Overview Work Items |
QUANTITY |
DESCRIPTION |
| SERVICE SWITCHES |
|
| A. Up to 100 AMPS |
0 |
|
| B. 101 Up to 200 AMPS |
0 |
|
| C. 201 Up to 600 AMPS |
0 |
|
| D. 601 Up to 1200 AMPS |
0 |
|
| E. Over 1200 AMPS |
0 |
|
| SER. ENT. & FDR COND (EACH SET) |
|
| A. Up to #2 CONDUCTOR |
0 |
|
| B. Over #2 to 1/0 |
0 |
|
| C. Over 1/0 to 250 MCM |
0 |
|
| D. Over 250 MCM |
0 |
|
| PANELS |
|
| A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs |
0 |
|
| B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs |
0 |
|
| C. 3 Phase Up to 225 AMPS |
0 |
|
| D. 3 Phase Over 225 AMPS |
0 |
|
| ELEVATORS / ESCALATORS / MATERIAL LIFTS |
|
| A. Total No. of Elevators / Escalators / Material Lifts |
11 |
|
| B. Each Additional 10 Floors Or Less |
0 |
|
| BOILER CONTROLS |
0 |
|
| OBJECTION ID |
OBJECTION CODE |
OBJECTION DESCRIPTION & COMMENTS |
STAT |
FIRST |
LATEST |
RESLVD |
| |
| 001 |
(308) |
CONDUCTORS ARE NOT PROPERLY INSTALLED/TERMINATED (ALL FLOORS)IN ALL CONTROL PANELS EGC IS DOUBLE LUGGED. ART. 110.14(A) |
RSLV |
07/09/2018 |
07/09/2018 |
07/23/2018 |
| |
| 002 |
( 14) |
CIRCUIT OVERCURRENT PROTECTION DEVICE IS OF IMPROPER SIZE (BASEMENT)ELEVATOR F, AND E LIGHTING DISCO'S ARE OVER FUSED, 30 AMPS ON #12AWG. ART. 240.3 |
RSLV |
07/09/2018 |
07/09/2018 |
07/23/2018 |
| |
| 003 |
( 14) |
CIRCUIT OVERCURRENT PROTECTION DEVICE IS OF IMPROPER SIZE (BASEMENT)SMALL SERVICE ELEVATOR OVER FUSED AT 60 AMP MAX 30 AMP. ART. 240.3 |
RSLV |
07/09/2018 |
07/09/2018 |
07/23/2018 |
| |
| 004 |
( 16) |
DEFECTIVE LIGHTING FIXTURES ARE IN USE (BASEMENT)ELEVATORS C AND ONE NEXT TO IT, A AND B HAVE DEFECTIVE LIGHTING ATTHE TOP OF CAR. ART. 110.2(A) |
RSLV |
07/09/2018 |
07/09/2018 |
07/23/2018 |
| |
| 005 |
( 17) |
DEFECTIVE SWITCHES ARE IN USE (BASEMENT) LIGHTS INSIDE ELEVATOR (C) DEFECTIVE. ART. 620.53 |
RSLV |
07/09/2018 |
07/09/2018 |
07/23/2018 |
| |
| 006 |
(188) |
MEANS OF POWER DISCONNECT NOT PROVIDED AS PER CODE (BASEMENT) DISCO'S FOR RETAIL ELEVATOR ARE NOT LABELED. ART. 110.22 |
RSLV |
07/09/2018 |
07/09/2018 |
07/23/2018 |
| |
| 007 |
( 7) |
EMT IS NOT PROPERLY SUPPORTED (TYPE:EMT) (BASEMENT) ELEVATOR E PIPE NOT SUPPORTED ABOVE DISCO. ART. 358.30 |
RSLV |
07/09/2018 |
07/09/2018 |
07/23/2018 |
| |
| 008 |
(176) |
INSTALLATION DOES NOT MEET CODE REQUIREMENTS (CELLAR)ALL PIT RECEPTACLES FOR OIL MIX PUMP HAS NOT BEEN INSTALLED. ART.110.2 |
RSLV |
07/09/2018 |
07/09/2018 |
07/23/2018 |
| |
| 009 |
( 18) |
DEFECTIVE RECEPTACLES ARE IN USE (CELLAR) ELEVATOR G PIT HAS DEFECTIVE GFCI. ART. 620.85 |
RSLV |
07/09/2018 |
07/09/2018 |
07/23/2018 |
| |
| 010 |
(231) |
NO OTHER OUTLET (CELLAR) ELEVATOR G RECEPTACLE FOR PUMP NOT SINGLE. |
RSLV |
07/09/2018 |
07/09/2018 |
07/23/2018 |
| |
| 011 |
( 14) |
CIRCUIT OVERCURRENT PROTECTION DEVICE IS OF IMPROPER SIZE (ROOF)CKT BREAKER PANEL IN ELEVATOR ROOM FUSED AT 125 AMP ON #3 AWG. ART.240.3 |
RSLV |
07/09/2018 |
07/09/2018 |
07/23/2018 |
| |
| 012 |
( 16) |
DEFECTIVE LIGHTING FIXTURES ARE IN USE (ROOF) RETAIL ELEVATOR #1 LIGHTS NOT WORKING. ART. 110.2 |
RSLV |
07/09/2018 |
07/09/2018 |
07/23/2018 |
| |
| 013 |
(308) |
CONDUCTORS ARE NOT PROPERLY INSTALLED/TERMINATED (ROOF) DOUBLE LUGGING ON MOTOR ENCLOSURE ON ROOF. ART. 110.14 |
RSLV |
07/09/2018 |
07/09/2018 |
07/23/2018 |
| |
| 014 |
(320) |
NO GUARDS FOR LAMPHOLDERS (ROOF)ELEVATOR A TOP OF CAR HAS NO GUARD FOR LIGHTING FIXTURE. ART. 620.4 |
RSLV |
07/09/2018 |
07/09/2018 |
07/23/2018 |
| |
| 015 |
( 33) |
KNOCKOUTS ARE NOT CLOSED IN OUTLET BOX (ROOF) KO'S ON 1900 BOXES IN MOTOR ROOM. ART. 110.12(A) |
RSLV |
07/09/2018 |
07/09/2018 |
07/23/2018 |