Electrical Application Details for App #: B414023
Premises: 312 GARFIELD PLACE BROOKLYN BIN: 3025135     Block: 1075   Lot: 28
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 312 GARFIELD PL Census Tract:   165 Health Area:  4500
LOFT-CELLER Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11215 Community Board:   306
DOB Cross Street(s):    8 AVENUE,    PROSPECT PARK WEST
Status:   C - JOB IS SIGNED OFF 04/26/2023 Balance Paid By Owner
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  07/08/2016 11:06 AM
Application Entered:   07/08/2016 Job Start Date:   07/08/2016
Last Change:   04/26/2023 Job End Date:   06/08/2017
Appointment Status:   
Last Inspection By:   ELLIS DAVID       On     04/24/2023      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011485 Licensee Name: BENJAMIN DREBIN
Firm: 002950 Firm Name: ACCURATE ELEC'L CORP.
Firm Phone: 718-606-9181  Firm Address: 11-07 43RD ROAD LONG ISLAND CITY NY 11101 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
7 - HVAC WIRING
Total Fee:  $221.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   B - Two Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JACOB BERGER
Owner Business Name: GARFIELD RE.LLC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  1  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL    32  20  13           
001                   
002                   
003                   
004                   
005    55  20  40           
Buildings Total 87  40  53                
Total Units : 192 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 2 #4-Wire 0 #10-Wire 0
Existing Meters 2 + New Meters 2 - Removed Meters 2 = Total Meters 2

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 07/08/2016 Notice: 1 - FIRST NOTICE 04/05/2023
Power Issued: 07/08/2016 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  N/A

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B414023
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/08/2023 03/08/2023 DIT J (34) (0) Y
INSPECTION COMMENTS: JOB IN PROGRESS , FULL INSPECTION REQUIRED
 
(2) 04/05/2023 04/05/2023 KVF V (20) (6)
INSPECTION COMMENTS: INSPECTION COMPLETE, SELF CERT OBJECTIONS ISSUED
 
(3) 04/18/2023 04/18/2023 PP1 J Y (0) (0)
INSPECTION COMMENTS: CERTIFIED - OBJ-23-000015975
 
(4) 04/18/2023 04/18/2023 PP1 J Y (0) (0)
INSPECTION COMMENTS: CERTIFIED - OBJ-23-000015978
 
(5) 04/18/2023 04/18/2023 PP1 J Y (0) (0)
INSPECTION COMMENTS: CERTIFIED - OBJ-23-000015979
 
(6) 04/18/2023 04/18/2023 PP1 J Y (0) (0)
INSPECTION COMMENTS: CERTIFIED - OBJ-23-000015980
 
(7) 04/18/2023 04/18/2023 PP1 J Y (0) (0)
INSPECTION COMMENTS: CERTIFIED - OBJ-23-000015981
 
(8) 04/24/2023 04/24/2023 EID C R (0) (0)
INSPECTION COMMENTS: CERTIFIED - OBJ-23-000016728

OBJECTION FOR APPLICATION #: B414023
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (176) INSTALLATION DOES NOT MEET CODE REQUIREMENTS
(FLOOR: 001) ART 422.30-35 MICROWAVE DISCO SWITCH IS NOT AS PER CODE
RSLV 04/05/2023 04/05/2023 04/18/2023
 
002 ( 30) OUTLET BOXES ARE NOT SECURED
(FLOOR: 001) ART.314.23 COUNTER TOP GFCI ON 1ST FLOOR NOT SECURED
RSLV 04/05/2023 04/05/2023 04/18/2023
 
003 (125) PROTECTION OF CONDUCTORS NOT INSTALLED AS PER CODE
(ALL FLOORS)ART 410.40-46 ALL WALL MOUNT LIGHT ARE NOT PROPERLY BONDED
RSLV 04/05/2023 04/05/2023 04/24/2023
 
004 (176) INSTALLATION DOES NOT MEET CODE REQUIREMENTS
(ALL FLOORS)ART.314.20 SLEEVES REQUIRED FOR ALL LIGHT SWITCHES AND OUTLETRECEPTACLES
RSLV 04/05/2023 04/05/2023 04/18/2023
 
005 (176) INSTALLATION DOES NOT MEET CODE REQUIREMENTS
(BASEMENT)ART250.148 LIGHT SWITCH NEAR JACUZZI AREA MISSING EGC BOND
RSLV 04/05/2023 04/05/2023 04/18/2023
 
006 ( 29) OUTLET BOXES ARE NOT COVERED
(BASEMENT)ART.314.25 LIGHT SWITCH NEAR SHOWER IN BASEMENT IS NOT COVERED ASPER CODE
RSLV 04/05/2023 04/05/2023 04/18/2023