Electrical Application Details for App #: B413165
Premises: 128 16 STREET BROOKLYN BIN: 3024112     Block: 1052   Lot: 17
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 128 16TH ST Census Tract:   141 Health Area:  4700
16TH STREET Admin Area:   B - BROOKLYN Inspection Area:   F
BROOKLYN, NY 11215 Community Board:   307
DOB Cross Street(s):    4 AVENUE,    5 AVENUE
Status:   C - JOB IS SIGNED OFF 12/23/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  06/20/2016 1:19 PM
Application Entered:   06/20/2016 Job Start Date:   06/20/2016
Last Change:   12/23/2016 Job End Date:   09/01/2016
Appointment Status:   
Last Inspection By:   CAMPBELL, C       On     11/30/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 012818 Licensee Name: JASON P SAMPOGNA
Firm: 004672 Firm Name: TAURUS ELEC'L CONT'G INC
Firm Phone: 718-207-7765  Firm Address: 200 6TH STREET, SUITE 3G BROOKLYN NY 11215 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
S - SUSTAINABLE ENERGY - GENERAL
Total Fee:  $70.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   B - Two Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JOSEPH LEVINE
Owner Business Name: NA
Authorized Representative:  JASON SAMPOGNA
Relationship To Owner:   MASTER ELECTRICIAN


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  2  2 SET #10 FEEDERS
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
ROF              15         
Buildings Total                       
Total Units : 4 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  ELECTRICAL PERMIT FOR 15LG 315 WATT MODULES WITH ENPHASE 250 MICROINVERTERS, #10 FEEDERS TO 60A DISCO SWITCH W/ VISIBLEBLADE 40A FUSES - CONNECTING TO 2 METERS - 1) 100A MAIN BREAKER, 125A PANEL RATING, 2POLE 20A BREAKER CONNECTING. METER#2 = LINE SIDE TAP CONNECTION 60A MAIN BREAKER

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B413165
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/30/2016 12/01/2016 CLC C (40) (0) Y
INSPECTION COMMENTS: INSPECTION PASS




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.