BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B409521
Premises: 430 ALBEE SQUARE BROOKLYN BIN: 3425729     Block: 146   Lot: 51
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 436 ALBEE SQ Census Tract:   15 Health Area:  1100
ENTIRE Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11201 Community Board:   302
Related Job Number:    320917665
DOB Cross Street(s):   GOLD STREET,    FULTON STREET
Status:   C - JOB IS SIGNED OFF 02/22/2018
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  04/01/2016 11:45 AM
Application Entered:   04/01/2016 Job Start Date:   04/01/2016
Last Change:   02/22/2018 Job End Date:   04/01/2017
Appointment Status:   
Last Inspection By:   ELLIS DAVID       On     02/21/2018      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012311 Licensee Name: MOSES ROSENBERGER
Firm: 004090 Firm Name: HIVOLTS ELECTRICAL INC
Firm Phone: 718-855-4346  Firm Address: 21 HERKIMER PLACE BROOKLYN NY 11216 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
3 - ELEVATOR/ESCALATOR/MATERIAL LIFT
6 - GENERAL WIRING
7 - HVAC WIRING
Total Fee:  $1,633.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: ALBEE SQUARE, LLC
Authorized Representative:  YOEL GOLDMAN
Relationship To Owner:   PARTNER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL    25  10    10  25  14  110  24     
001    25  10    10  25  24     
002    25  10    10  25         
003    60  25    19  60  16     
004    64  80    80  64  24         
005    64  80    80  64  24         
006    40  50    50  40  15         
007    40  50    50  40  15         
008    40  50    50  40  15         
009    40  50    50  40  15         
010    40  50    50  40  15         
011    40  50    50  40  15         
012    48  60    60  48  18         
013    48  60    60  48  18         
014    48  60    60  48  18         
015    48  60    60  48  18         
016    48  60    60  48  18         
017    48  60    60  48  18         
018    48  60    60  48  18         
019    48  60    60  48  18         
020    48  60    60  48  18         
021    48  60    60  48  18         
022    48  60    60  48  18         
023    48  60    60  48  18         
024    48  60    60  48  18         
025    48  60    60  48  18         
026    48  60    60  48  18         
027    48  60    60  48  18         
028    48  52    48  48         
ROF    12    10  12  20  16     
Buildings Total 1331  1535    1527  1331     574     86      
Total Units : 6384 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 02/12/2018
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B409521
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/11/2018 02/12/2018 CLC V (300) (3)
INSPECTION COMMENTS: INSPECTION FAIL
 
(2) 02/21/2018 02/22/2018 EID C R (35) (0)
INSPECTION COMMENTS: OBJ. REMOVED. PASS

OBJECTION FOR APPLICATION #: B409521
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(FLOOR: 003)ENTIRE 3RD FLOOR BOXES RECEPTACLES AREN'T MOUNTED PROPERLY 406.4 A
RSLV 02/11/2018 02/11/2018 02/21/2018
 
002 ( 33) KNOCKOUTS ARE NOT CLOSED IN OUTLET BOX
(ALL FLOORS) THOUGH OUT KO MISSING BALCONY OUTLET BOXES
RSLV 02/11/2018 02/11/2018 02/21/2018
 
003 (999) OTHER
(ALL FLOORS) ALL KITCHEN COUNTER OUTLETS NEED COLLARS 314.20
RSLV 02/11/2018 02/11/2018 02/21/2018