Electrical Application Details for App #: B408794
Premises: 300 SCHERMERHORN STREET BROOKLYN BIN: 3420391     Block: 172   Lot: 24
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 300 SCHERMERHORN ST Census Tract:   41
2 Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11217 Community Board:   302
Special Place Name:   HOLIDAY INN
DOB Cross Street(s):   BOND STREET,    NEVINS STREET
Status:   C - JOB IS SIGNED OFF 05/25/2016
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   03/17/2016 Job Start Date:   03/07/2016
Last Change:   05/25/2016 Job End Date:   09/07/2016
Appointment Status:   
Last Inspection By:   THOMAS, PATRICIA       On     05/24/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 009615 Licensee Name: ROBERT COVELLO
Firm: 001205 Firm Name: ROBERT S. COVELLO
Firm Phone: 718-786-7390  Firm Address: 51-20 35TH STREET L.I.C. NY 11101 

Work Started or Filed by Others: NO
Work Category:   U - UN-TAGGED SIGN Work To Be Done:  
6 - GENERAL WIRING
9 - OTHER
Total Fee:  $130.00
Other Work:   SIGN TAG
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   H - Hotel
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: SEEN KEI CHIEW
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 1 Tags:

Sign Dimensions : 19 Ft 4 In  BY  3 Ft 1 In  Total Sq. Ft. of Sign: 60
Sign Type : A
Total Circuits: 1 Total Lamps: 0
Watts (Lamps): 0 Number of Trans: 2 VA of Each Trans: 1
Total Watts or VA: 2 A.W. Gauge of Wire: 12 No. of Sockets Per Circuit: 0
Material/Gauge: 3/16"ALUMINUM, ACRYLIC
Sign Maker : TRU-ART SIGN COMPANY
Sign Maker Address: 187 NORTH MAIN STREET, FREEPORT, NY 11520
Shop Address:
Shop Phone:
Shop Location Comments:
Sign Text: HOLIDAY INN (H LOGO)

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  TAG SIGN ON WALL AND INSPECT EXISTING CONNECTION AND GENERALWIRING TO SIGN. READING-(H LOGO)HOLIDAY INN

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B408794
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/24/2016 05/25/2016 PAT C (75) (0) Y
INSPECTION COMMENTS: PASS