BIS Menu  |  Plumb. Inspections  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B407677
Premises: 461 DEAN STREET BROOKLYN BIN: 3398591     Block: 1118   Lot: 2
   

DOB NOW: Inspections


Filed: 461 DEAN ST Census Tract:   129.02 Health Area:  2600
SUB CELLAR, CELLAR 1-24 FLOORS Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11217 Community Board:   306
Related Job Number:    320623214
DOB Cross Street(s):   FLATBUSH AVENUE,    6 AVENUE
Status:   K - CLOSED/CANCELLED 04/13/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  02/24/2016 2:00 PM
Application Entered:   02/24/2016 Job Start Date:   02/24/2016
Last Change:   04/13/2016 Job End Date:   02/28/2018
Appointment Status:   
Last Inspection By:   ELLIS DAVID       On     04/13/2016      
Field Disp:   K - OK TO CANCEL
Energize Recommendation:  
Objection Disposition:  

License #: 012213 Licensee Name: LEONARD HARRINGTON
Firm: 003932 Firm Name: ALLAN/BRITE-WAY ELEC'L CO
Firm Phone: 646-694-8914  Firm Address: 228 EAST 45TH STREET, 9TH FL NEW YORK NY 10017 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
2 - TEMPORARY CONSTRUCTION
L - LIGHTING WORK
T - TEMPORARY LIGHT & POWER
Total Fee:  $2,133.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   Yes
Job Number:  320623214
Building Used As:   Z - Other
Store / Other:   RESIDENTAL
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: ROBERT SANNA
Owner Business Name: ATLANTIC YARD
Authorized Representative:  SONYA CONVINGTON
Relationship To Owner:   MANAGER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  2  2-200A
C. 201 Up to 600 AMPS  3  3-400A
D. 601 Up to 1200 AMPS  1  1-1200A
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  1-250AL
D. Over 250 MCM  12  8-750AL,4-500AL
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  6  6-200A
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
SC1    10  20                   
CEL    10  20                   
001    30  20                   
002    30  20                   
003    30  20                   
004    30  20                   
005    30  20                   
006    30  20                   
007    30  20                   
008    30  20                   
009    30  20                   
010    25  15                   
011    25  15                   
012    25  15                   
013    25  15                   
014    25  15                   
015    25  15                   
016    25  15                   
017    25  15                   
018    15  10                   
019    15  10                   
020    15  10                   
021    15  10                   
022    15  10                   
023    15  10                   
024    15  10                   
Buildings Total 595  410                      
Total Units : 1005 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  NY-16103-00 TL&P

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B407677
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 04/13/2016 04/13/2016 EID K (20) (0) Y
INSPECTION COMMENTS: CHANGE OF ADDRESS: SCOPE COVERED UNDER APP# B407895