Electrical Application Details for App #: B406771
Premises: 38 6 AVENUE BROOKLYN BIN: 3418421     Block: 1118   Lot: 3
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 38 6TH AV Census Tract:   129.02 Health Area:  2600
GROUND Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11217 Community Board:   306
DOB Cross Street(s):   PACIFIC STREET,    DEAN STREET
Status:   C - JOB IS SIGNED OFF 10/09/2018
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  02/03/2016 10:03 AM
Application Entered:   02/03/2016 Job Start Date:   03/01/2016
Last Change:   10/09/2018 Job End Date:   03/01/2019
Appointment Status:   
Last Inspection By:   NAJI PHILLIIPS       On     09/28/2018      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012512 Licensee Name: WARREN BUBAK
Firm: 003078 Firm Name: KNIGHT ELEC'L SERV. CORP.
Firm Phone: 212-989-2333  Firm Address: 599 11TH AVENUE, 7TH FLOOR NEW YORK NY 10036 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
3 - ELEVATOR/ESCALATOR/MATERIAL LIFT
Total Fee:  $1,081.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: TISHMAN CONSTRUCTION CORP
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  7  
B. Each Additional 10 Floors Or Less  2  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 09/04/2018
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B406771
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/23/2018 05/24/2018 SGY N (15) (0) Y
INSPECTION COMMENTS: CONTRACTOR NO SHOW.
 
(2) 09/04/2018 09/04/2018 NJP V (105) (6)
INSPECTION COMMENTS: CORRECT OBJECTIONS. 7 ELEVATORS WAS INSPECTED CONTRACTOR HAS 9 ON APP. ELEV PE1- ID#3P15344 /PE2- ID#3P15345/PE3- ID#3P15477. CAR GARAGE FE7- ID#3F6193/ FE8-ID#3F6199. FRIEGHT ELEVATOR 5- ID#3P15346/ ELEV 6- ID#3P15347.
 
(3) 09/28/2018 10/01/2018 NJP C R (30) (0)
INSPECTION COMMENTS: OBJECTIONS RESOLVED THE JOB IS OK.

OBJECTION FOR APPLICATION #: B406771
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 16) DEFECTIVE LIGHTING FIXTURES ARE IN USE
(ALL FLOORS)ELEVATOR PIT/TOP OF CAR LIGHT DEFECTIVE OR MISSING LIGHT BULB.(AMEND 110.2A)
RSLV 09/04/2018 09/04/2018 09/28/2018
 
002 (999) OTHER
(ALL FLOORS)GND CONDUCTOR NOT PROPERLY TERMINATED IN DISCONNECTS AND ELEVATORCABINETS.(ART 110.14)
RSLV 09/04/2018 09/04/2018 09/28/2018
 
003 (999) OTHER
(ALL FLOORS)HIGH VOLTAGE AND LOW VOLTAGE INSTALLED IN SAME RACEWAY.(AMEND 300.3)
RSLV 09/04/2018 09/04/2018 09/28/2018
 
004 (999) OTHER
(ALL FLOORS) TRANSFORMER RACEWAYS ARE NOT PROPERLY BONDED.
RSLV 09/04/2018 09/04/2018 09/28/2018
 
005 (999) OTHER
(ALL FLOORS)THROUGHOUT ELEV DISCONNECTS CONDUCTORS ARE DOUBLE LUGGED ONTERMINALS.(ART 110.14)
RSLV 09/04/2018 09/04/2018 09/28/2018
 
006 ( 36) CONDUCTORS ARE NOT PROPERLY COLOR CODED
(ROOF) ALL TRANSFORMER FOR ELEVATORS HIGH VOLTAGE CONDUCTORS ARE NOTIDENTIFIED PROPERLY. (ART 200.6)
RSLV 09/04/2018 09/04/2018 09/28/2018