Electrical Application Details for App #: B399678
Premises: 372 MONROE STREET BROOKLYN BIN: 3051478     Block: 1820   Lot: 16
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 372 MONROE ST Census Tract:   265
BSMT/THROUGHOUT Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11221 Community Board:   303
DOB Cross Street(s):   TOMPKINS AVENUE,    THROOP AVENUE
Status:   C - JOB IS SIGNED OFF 07/05/2016
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   08/17/2015 Job Start Date:   08/06/2015
Last Change:   07/05/2016 Job End Date:   08/01/2016
Appointment Status:   
Last Inspection By:   DAMISO COOTE       On     06/29/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011169 Licensee Name: LAWRENCE WALSH
Firm: 002541 Firm Name: BDS ELECTRIC CORP.
Firm Phone: 718-598-0000  Firm Address: 220-04 HEMPSTEAD AVENUE QUEENS VILLAGE NY 11429 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $143.00
Hurricane Sandy Damage:   No
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   B - Two Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MICHAEL KANDINOV
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  3  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  2  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS               
001  1A  15  16  12  15             
002  2B  13  18  12  13             
Buildings Total 34  40  30  34                
Total Units : 146 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 3 #4-Wire 0 #10-Wire 0
Existing Meters 2 + New Meters 3 - Removed Meters 2 = Total Meters 3

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 08/17/2015 Notice: 1 - FIRST NOTICE 05/12/2016
Power Issued: 08/17/2015 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  GUT/RENO 2 FAM- 3 100A 220V SINGLE PHASE METERS

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B399678
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/10/2016 05/12/2016 CJH V (88) (11)
INSPECTION COMMENTS: OVEN INFO NEEDED
 
(2) 05/31/2016 06/01/2016 CCH J Y (90) (0)
INSPECTION COMMENTS: JOB FAIL # 14 WIRE CORD FROM A/C TO BLOWER IN APT
 
(3) 06/29/2016 07/01/2016 DIT C R (40) (0)
INSPECTION COMMENTS: JOB PASS

OBJECTION FOR APPLICATION #: B399678
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(FLOOR: 001)001 FL PENINSULAR COUNTER TOP EXTENDED OVER 6" 210.52 C5
RSLV 05/10/2016 05/10/2016 05/31/2016
 
002 ( 18) DEFECTIVE RECEPTACLES ARE IN USE
(FLOOR: 002) 002 KIT COUNTER TOP RECEPT 110.2
RSLV 05/10/2016 05/10/2016 05/31/2016
 
003 (282) MINIMUM NUMBER OF SMALL APPLIANCE CIRCUITS
(FLOOR: 002) 002 TWO CKT NOT PROVIDED 210.52 (B1)
RSLV 05/10/2016 05/10/2016 05/31/2016
 
004 (283) SMALL APPLIANCE OUTLETS NOT PROPERLY LOCATED
(FLOOR: 002) 002 WINE COOLER CKT 210.52(C5)
RSLV 05/10/2016 05/10/2016 05/31/2016
 
005 ( 53) GFCI HAS NOT BEEN PROVIDED
(FLOOR: 002) 002 KIT COUNTER TOP RECEPT NOT GFCI 210.8
RSLV 05/10/2016 05/10/2016 05/31/2016
 
006 (999) OTHER
(FLOOR: 003) 003 BATH GFCI NOT TR 406.11
RSLV 05/10/2016 05/10/2016 05/31/2016
 
007 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
(CELLAR) CELLAR PNL NOT LABELLED 408.4
RSLV 05/10/2016 05/10/2016 05/31/2016
 
008 (999) OTHER
(CELLAR) CELLAR BATH RM CKT WITH RECEPT 210.11C3
RSLV 05/10/2016 05/10/2016 05/31/2016
 
009 (999) OTHER
(ROOF) ROF AC UNITS WHT USED AS HOT 200.7
RSLV 05/10/2016 05/10/2016 05/31/2016
 
010 (999) OTHER
(ROOF) ROF AC UNITS GND NOT PROPERLY SIZE 250.122
RSLV 05/10/2016 05/10/2016 05/31/2016
 
011 (999) OTHER
(ROOF) ROF AC UNITS #14 IN USED 219.19 (A1)
RSLV 05/10/2016 05/10/2016 06/29/2016