BIS Menu  |  Elevators  |  Electrical Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B399350
Premises: 337 DEGRAW STREET BROOKLYN BIN: 3426116     Block: 414   Lot: 43
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 337 DEGRAW ST Census Tract:   75 Health Area:  2500
ENTIRE Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11231 Community Board:   306
Related Job Number:    320011928
DOB Cross Street(s):   COURT STREET,    SMITH STREET
Status:   C - JOB IS SIGNED OFF 10/11/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/07/2015 1:18 PM
Application Entered:   08/07/2015 Job Start Date:   08/07/2015
Last Change:   10/11/2017 Job End Date:   05/15/2016
Appointment Status:   
Last Inspection By:   DALTON HENLON       On     08/17/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011827 Licensee Name: JOSEPH P CANTALINO
Firm: 004046 Firm Name: RIGHTWAY ELECTRICAL INC
Firm Phone: 212-334-6918  Firm Address: 18 ORCHARD STREET, 1ST FL NEW YORK NY 10002 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $321.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   E - Four Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MICHAEL SUBHIA
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  5  100A 1PH
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  4  #3W
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  4  16 POLE
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL    10  20    20         
001    10  30    12  30             
MZ1    10  30    12  30             
002    10  30    12  30             
003    10  30    12  30             
004    10  30    12  30             
ROF        20         
Buildings Total 60  171    69  171     23           
Total Units : 494 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 5 #4-Wire 0 #10-Wire 0
Existing Meters 5 + New Meters 5 - Removed Meters 5 = Total Meters 5

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 08/07/2015 Notice: 1 - FIRST NOTICE 06/28/2017
Power Issued: 08/07/2015 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B399350
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/28/2017 06/28/2017 EID V (50) (5)
INSPECTION COMMENTS: INSPECTION COMPLETED. OBJ ISSUED.
 
(2) 08/17/2017 08/18/2017 DAH C R (19) (0)
INSPECTION COMMENTS: THE VIOLATIONS ARE RESOLVED

OBJECTION FOR APPLICATION #: B399350
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (279) WATER METER JUMPER IS MISSING/IMPROPER
(CELLAR) METER JUMPER NOT INSTALLED
RSLV 06/28/2017 06/28/2017 08/17/2017
 
002 ( 5) SERVICE GROUNDING CONDUCTOR HAS NOT BEEN INSTALLED PROPERLY
(CELLAR) GEC CONDUCTOR NOT PROVIDED TO WATER MAIN.
RSLV 06/28/2017 06/28/2017 08/17/2017
 
003 (999) OTHER
(CELLAR)SERVICE SWITCHES ARE NOT PROPERLY MARKED AS SERVICE (ART 230.70 B)
RSLV 06/28/2017 06/28/2017 08/17/2017
 
004 (999) OTHER
(CELLAR)PLP PNL: SIMULTANEOUS TRIP ARE NOT PROVIDED FOR ALL NECESSARY CKTS.(ART. 210.4 B)
RSLV 06/28/2017 06/28/2017 08/17/2017
 
005 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
(ROOF)WIRING FOR A/C UNITS: BX CABLES AND METAL BOXES INSTALLED EXPOSED/MATERIALS ARE NOT FOR OUTDOOR USE
RSLV 06/28/2017 06/28/2017 08/17/2017