BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B397752
Premises: 146 WILLOW STREET BROOKLYN BIN: 3001773     Block: 234   Lot: 68
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 146 WILLOW ST Census Tract:   3.01 Health Area:  2300
WILLOW STREET Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11201 Community Board:   302
DOB Cross Street(s):   CLARK STREET,    PIERREPONT STREET
Status:   C - JOB IS SIGNED OFF 12/16/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  07/01/2015 1:41 PM
Application Entered:   07/01/2015 Job Start Date:   07/01/2015
Last Change:   12/16/2016 Job End Date:   07/01/2017
Appointment Status:   
Last Inspection By:   DALTON HENLON       On     12/13/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 010587 Licensee Name: HARRY FRENKEL
Firm: 002697 Firm Name: APOLLO ELECTRIC INC.
Firm Phone: 212-627-2561  Firm Address: 127 WEST 24TH ST,5TH FL STE#A NEW YORK NY 10011 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
3 - ELEVATOR/ESCALATOR/MATERIAL LIFT
6 - GENERAL WIRING
7 - HVAC WIRING
Total Fee:  $963.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: SHAHRZAD KHAYAMI
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  3  
B. Over #2 to 1/0  3  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  2  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  2  
C. 3 Phase Up to 225 AMPS  2  
D. 3 Phase Over 225 AMPS  1  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  1  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL    15  15      18         
BAS    30  25  20           
001    30  22  20           
002    30  22    20           
003    30  22    20           
004    30  22    20               
ROF    10      16         
Buildings Total 170  138  107       38           
Total Units : 462 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 1
Existing Meters 11 + New Meters 1 - Removed Meters 11 = Total Meters 1

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 07/01/2015 Notice: 1 - FIRST NOTICE 11/22/2016
Power Issued: 07/01/2015 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B397752
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/21/2016 11/22/2016 CLC V (45) (5)
INSPECTION COMMENTS: INSPECTION FAIL
 
(2) 12/13/2016 12/16/2016 DAH C R (11) (0)
INSPECTION COMMENTS: THE VIOLATIONS RESOLVED

OBJECTION FOR APPLICATION #: B397752
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (340) RECEPTACLES NOT TAMPERPROOF
(FLOOR: 001) CLOCK OUTLETS THROUGH OUT NOT TR 406.11
RSLV 11/21/2016 11/21/2016 12/13/2016
 
002 ( 53) GFCI HAS NOT BEEN PROVIDED
(FLOOR: 001) KITCHEN PLUG MOLD NOT GFCI PROTECTED
RSLV 11/21/2016 11/21/2016 12/13/2016
 
003 ( 53) GFCI HAS NOT BEEN PROVIDED
(FLOOR: 002) BATH RM OUTLET NOT GFCI PROTECTED
RSLV 11/21/2016 11/21/2016 12/13/2016
 
004 ( 5) SERVICE GROUNDING CONDUCTOR HAS NOT BEEN INSTALLED PROPERLY
(BASEMENT) SERVICE GROUND NOT INSTALLED PRIOR TO INSPECTION
RSLV 11/21/2016 11/21/2016 12/13/2016
 
005 (999) OTHER
(CELLAR) BATH RM GFCI CKT ON WITH LAUNDRY RM GFCI 210.11 C 3
RSLV 11/21/2016 11/21/2016 12/13/2016



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.