| NYC Department of Buildings | ||
| Electrical Application Details for App #: B396336 | ||
| Premises: 1145 FULTON STREET BROOKLYN | BIN: 3251624 Block: 1997 Lot: 43 |
| Printable (PDF) version of this Permit | |||||||||||
| DOB NOW: Inspections | |||||||||||
| Filed: | 1147 FULTON ST | Census Tract: 227 | Health Area: 1300 | |
| BASEMENT / GROUND / 2ND / 3RD | Admin Area: B - BROOKLYN | Inspection Area: D | ||
| BROOKLYN, NY 11238 | Community Board: 303 | |||
| Special Place Name: BETTER HEALTH PHARMACY | ||||
| DOB Cross Street(s): CLAVER PLACE, FRANKLIN AVENUE | |||
| Status: E - ABANDONED 08/22/2025 | |||
| Request Type: A - APPLICATION | eFiled: YES | Permit Issued: 05/28/2015 11:15 AM | |
| Application Entered: 05/28/2015 | Job Start Date: 05/29/2015 | ||
| Last Change: 08/22/2025 | Job End Date: 06/30/2015 | ||
| COMPLETION FEE WAS BILLED | |||
| Appointment Status: | |||
| Last Inspection By: On | |||
| Field Disp: | |||
| Energize Recommendation: | |||
| Objection Disposition: | |||
| License #: | 011368 | Licensee Name: | CHRISTOPHER J STABILE | |
| Firm: | 002791 | Firm Name: | STABILITY ELEC ENTERP INC | |
| Firm Phone: | 718-449-8800 | Firm Address: | 8762 20TH AVENUE BROOKLYN NY 11214-4804 | |
| Work Started or Filed by Others: NO | ||||||||
| Work Category: R - REHABILITATION | Work To Be Done:
6 - GENERAL WIRING |
Total Fee: $41.75 | ||||||
| Other Work: | ||||||||
| Work Related to a New or Amended Certificate of Occupancy: NO | ||||||||
| This Job Regulated by the NYC Energy Conservation Code: No | ||||||||
| Building Used As: Z - Commercial/Residential (2 Stores, 2 Apartments) | |||||||
| Special Cert Approval: | |||||||
| Advisory Board Approval: NOT APPLICABLE | |||||||
| Owner / Occup: | MOHAMMAD ISMAIL | ||||||
| Authorized Representative: | |||||||
| Relationship To Owner: | |||||||
|
|
| Floor | Apt. | Number Of Outlets | No. Of Fixtures |
Motors / Generators | Heaters | Transformers | ||||||
| Fixt | Receptacles | Switch | Num | Total HP KW | Num | Total KW | Num | Total KVA | ||||
| ATT | A/C | |||||||||||
| BAS | N/A | 1 | 2 | 1 | 1 | |||||||
| GND | N/A | 1 | 1 | 1 | ||||||||
| 002 | N/A | 2 | 2 | 2 | ||||||||
| 003 | N/A | 1 | 1 | 1 | ||||||||
| Buildings Total | 5 | 2 | 5 | 5 | ||||||||
| Total Units : 17 units | ||||||||||||
| Signs: | Field Connect: | 0 | Field Inspect: | 0 | Tags: | ||
| Meter Request to Utility | #3-Wire | 0 | #4-Wire | 0 | #10-Wire | 0 | |
| Existing Meters | 0 | + New Meters | 0 | - Removed Meters | 0 | = Total Meters | 0 |
| Power Auth Flag: | Objection Flag: | ||
| Power Requested: | Notice: | ||
| Power Issued: | Response: |
| Follow-Up: | |||
| Contractor's Comments: CONTRACTOR #00615 THIS APP. IS FILED FOR NEW PLP BRANCH CIRCUIT WIRING. EXISTING BOILER ROOM AND APARTMENT ACCESS STAIRWELL LTG. HAVE BEEN REWIRED AND SEGREGATED TO THE PLP PANEL. SCOPE OF WORK INCLUDES: APPROX. 200 FT. EMT CONDUIT; 4- NEW, CEILING LED LTG. FIXTURES; AND NEW 4-POINT SWITCH CONTROL. | |||
|
|
| *NO INSPECTION RECORDS FOUND FOR ELECTRICAL APPLICATION NUMBER B396336 |
| INSP ID |
FIELD DATE |
DISP DATE |
INSP ID |
FLD DISP |
OBJ DISP |
ENRG REC |
TIME INSP |
REINSP DATE |
NEW OBJ |