BIS Menu  |  Elevators  |  Electrical Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B390647
Premises: 2042 PACIFIC STREET BROOKLYN BIN: 3038680     Block: 1439   Lot: 23
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 2042 PACIFIC ST Census Tract:   303 Health Area:  5200
BSMT, 1FL, 2FL Admin Area:   B - BROOKLYN Inspection Area:   E
BROOKLYN, NY 11233 Community Board:   316
Special Place Name:   BROOKLYN
DOB Cross Street(s):   HOWARD AVENUE,    SARATOGA AVENUE
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  01/07/2015 8:29 PM
Application Entered:   01/07/2015 Job Start Date:   01/15/2015
Last Change:   08/22/2025 Job End Date:   12/31/2015
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   DAMISO COOTE       On     03/03/2017      
Field Disp:   N - NO ACCESS
Energize Recommendation:  
Objection Disposition:  

License #: 010809 Licensee Name: JOHN L RICKFORD
Firm: 002075 Firm Name: R.J.ELECTRICAL CONTRACTOR
Firm Phone: 718-949-5466  Firm Address: 201-11 LINDEN BLVD ST. ALBANS NY 11412 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $79.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   B - Two Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MELISSA PISCIOTTA
Owner Business Name: CITYWIDE PROP SERVICES
Authorized Representative:  RICKFORD JOHN
Relationship To Owner:   ELECTRICAL CONTRACTOR


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  3  3-PANELS WITH 100 A MAINS
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  1-SET OF 3 #3 AWG
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 3 #4-Wire 0 #10-Wire 0
Existing Meters 2 + New Meters 1 - Removed Meters 0 = Total Meters 3

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 01/07/2015 Notice:  
Power Issued: 01/07/2015 Response:  

Follow-Up:
Contractor's Comments:  UPGRADING METER SERVICE FROM 70 AMPS 110 VOLTS TO 100 AMPS 110/208 VOLTS. ADD ONE (1) METER FOR PLP AND RELOCATE METERSOUTDOOR. NO OTHER WORK DONE.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B390647
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/14/2015 10/20/2015 WYF Z (0) (0) Y
INSPECTION COMMENTS: CANCELLED WITH OFFICE
 
(2) 11/23/2015 11/30/2015 CCH N (50) (0) Y
INSPECTION COMMENTS: N
 
(3) 03/03/2017 03/06/2017 DIT N (30) (0) Y
INSPECTION COMMENTS: CALLED CONTRACTOR NO SHOW / NO ACCESS




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Elevators  |  Electrical Applications  |  Electrical Inspection Work Order  |  Back