Electrical Application Details for App #: B388738
Premises: 226 LINDEN BOULEVARD BROOKLYN BIN: 3413702     Block: 5088   Lot: 30
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 226 LINDEN BLVD Census Tract:   820 Health Area:  5400
CELLAR - ROOF Admin Area:   B - BROOKLYN Inspection Area:   G
BROOKLYN, NY 11226 Community Board:   317
Related Job Number:    320373626
DOB Cross Street(s):   ROGERS AVENUE,    NOSTRAND AVENUE
Status:   C - JOB IS SIGNED OFF 02/26/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  11/14/2014 2:20 PM
Application Entered:   11/14/2014 Job Start Date:   11/14/2014
Last Change:   02/26/2016 Job End Date:   11/30/2015
Appointment Status:   
Last Inspection By:   JEFFERSON, CHARLES       On     02/23/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011877 Licensee Name: ANTHONY CERRITO
Firm: 003392 Firm Name: A & R ELEC'L MAINT. INC.
Firm Phone: 718-639-0800  Firm Address: 85-47 GRAND AVE ELMHURST NY 11373 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
7 - HVAC WIRING
8 - BOILER/BURNER WIRING
Total Fee:  $3,809.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: DANIEL SOLIMINE
Owner Business Name: G. FAZIO
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  2  2-30AMP
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  1-600AMP
D. 601 Up to 1200 AMPS  2  1200A 3P, 800A 3P
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  72  3#4
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  1  1-500 MCM
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  72  12/24 CIRC
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  3  200A 3P
D. 3 Phase Over 225 AMPS  2  800AMP
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL    40  43    40  30         
001    116  61    20  116             
002    82  70  10  50  82             
003    82  70  10  50  82             
004    82  70  10  50  82             
005    82  70  10  50  82             
006    82  70  10  50  82             
007    82  70  10  50  82             
008    56  60  40  56             
009    43  50  30  43             
ROF    10    10         
Buildings Total 757  637  74  402  757     35           
Total Units : 2662 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 2
Existing Meters 0 + New Meters 2 - Removed Meters 0 = Total Meters 2

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 11/14/2014 Notice: 1 - FIRST NOTICE 02/02/2016
Power Issued: 11/14/2014 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B388738
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/10/2015 12/14/2015 CCH V (269) (6)
INSPECTION COMMENTS: NEED CHECK BOILER ROOM
 
(2) 02/02/2016 02/02/2016 CJE V R (46) (1)
INSPECTION COMMENTS: SERVICE EQUIPMENT NEEDS TO BE BONDED.
 
(3) 02/23/2016 02/26/2016 CJE C R (18) (0)
INSPECTION COMMENTS: OBJECTIONS REMOVED

OBJECTION FOR APPLICATION #: B388738
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (211) RECEPTACLE IS NOT PROPERLY BONDED/GROUNDED
(ALL FLOORS) STOVE OUTLET
RSLV 12/10/2015 12/10/2015 02/02/2016
 
002 (328) CIRCUIT CONDUCTORS NOT GROUPED
(ALL FLOORS) CIRCURT NOT GROUP
RSLV 12/10/2015 12/10/2015 02/02/2016
 
003 ( 1) SERVICE EQUIPMENT ENCLOSURES ARE NOT BONDED TOGETHER
(CELLAR) BONDING SCREW ON ALL RACEWAY
RSLV 12/10/2015 12/10/2015 02/02/2016
 
004 (279) WATER METER JUMPER IS MISSING/IMPROPER
(CELLAR) METER NOT JUMP
RSLV 12/10/2015 12/10/2015 02/02/2016
 
005 ( 5) SERVICE GROUNDING CONDUCTOR HAS NOT BEEN INSTALLED PROPERLY
(CELLAR) GROUND NOT TO NEUTRAL LINK
RSLV 12/10/2015 12/10/2015 02/02/2016
 
006 (999) OTHER
(CELLAR) NO QUICK CONNECTOR 410.73
RSLV 12/10/2015 12/10/2015 02/02/2016
 
007 ( 1) SERVICE EQUIPMENT ENCLOSURES ARE NOT BONDED TOGETHER
(CELLAR) BONDING SCREW ON ALL RACEWAY.
RSLV 02/02/2016 02/02/2016 02/23/2016