Electrical Application Details for App #: B387825
Premises: 184 MONROE STREET BROOKLYN BIN: 3051316     Block: 1817   Lot: 36
   
Application Completed and Certified

Filed: 184 MONROE ST Census Tract:   245 Health Area:  2800
4 FLOORS + BSMT Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11216 Community Board:   303
DOB Cross Street(s):   BEDFORD AVENUE,    NOSTRAND AVENUE
Status:   C - JOB IS SIGNED OFF 05/28/2015
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  10/24/2014 4:01 PM
Application Entered:   10/24/2014 Job Start Date:   10/27/2014
Last Change:   05/28/2015 Job End Date:   12/27/2015
Appointment Status:   
Last Inspection By:   BANYA, E       On     04/21/2015      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 012571 Licensee Name: PANDELI GJINI
Firm: 003543 Firm Name: TECHNO-VOLT ELEC, INC
Firm Phone: 718-359-8070  Firm Address: 28-29 119TH STREET FLUSHING NY 11354 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
8 - BOILER/BURNER WIRING
Total Fee:  $1,165.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:   B - BOILER CONTROLS J-51 CERTIFICATION
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: PERRY NOTIAS
Owner Business Name: NOTIAS CONSTRACTION
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  2  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  22  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  1  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  22  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  1  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS    38  15    15               
001    38  75  15  35               
002    38  75  15  35               
003    38  75  15  35               
004    38  75  15  35               
Buildings Total 190  315  60  155                  
Total Units : 720 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 20 #4-Wire 1 #10-Wire 0
Existing Meters 21 + New Meters 21 - Removed Meters 21 = Total Meters 21

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 10/24/2014 Notice: 1 - FIRST NOTICE 04/06/2015
Power Issued: 10/24/2014 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B387825
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 04/02/2015 04/06/2015 CJH A E (130) (14) Y
INSPECTION COMMENTS: N
 
(2) 04/21/2015 04/27/2015 EBA C R E (60) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B387825
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
CELLAR SVC AREA COMMUNICATION BAR NOT INSTALLED 250.94
RSLV 04/02/2015 04/02/2015 04/21/2015
 
002 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
PLP GND CONDUCTOR NOT TERMINATED 250.112
RSLV 04/02/2015 04/02/2015 04/21/2015
 
003 (279) WATER METER JUMPER IS MISSING/IMPROPER
CELLAR SVC WATER METER JUMPER 250.53
RSLV 04/02/2015 04/02/2015 04/21/2015
 
004 (222) USING NON METALLIC SEALTITE NOT APPROVED
CELLAR BOOSTER PUMP CONTROLLER 356.10
RSLV 04/02/2015 04/02/2015 04/21/2015
 
005 (999) OTHER
CELLAR BOILER ROOM PNL CIRCUIT NOT GROUPED 210.4D
RSLV 04/02/2015 04/02/2015 04/21/2015
 
006 (999) OTHER
CELLAR BOILER ROOM PNL MULTI CIRCUIT NOT SIMUTANEOUSLY 210.4B
RSLV 04/02/2015 04/02/2015 04/21/2015
 
007 (999) OTHER
CELLAR SVC SWITCH DIS SWITCHES PLAZUE NOT PROVIDED 230.2E
RSLV 04/02/2015 04/02/2015 04/21/2015
 
008 (999) OTHER
REAR SUPER APT KITCHEN COUNTER TOP GFCI HOOD SHARE CIRCUIT 210.52 B2
RSLV 04/02/2015 04/02/2015 04/21/2015
 
009 (311) FIXTURE NOT APPROVED FOR DAMP/WET LOCATION
ALL FL THROUGHOUT BATHROOM LUMINARES 410.10
RSLV 04/02/2015 04/02/2015 04/21/2015
 
010 (999) OTHER
APT 4.5.6.9 KITCHEN COUNTER GFCI SHARE WITH LIGHTS CIRCUITS 210.52B2
RSLV 04/02/2015 04/02/2015 04/21/2015
 
011 (211) RECEPTACLE IS NOT PROPERLY BONDED/GROUNDED
ALL FL THROUGHOUT RECEPTICLES OUTLETS 250.146
RSLV 04/02/2015 04/02/2015 04/21/2015
 
012 (999) OTHER
APT 1,7,11,15 KITCHEN COUNTER TOP RECEPTICLES OUTLETS NOT LOCATED PROPERLY 210.52
RSLV 04/02/2015 04/02/2015 04/21/2015
 
013 ( 18) DEFECTIVE RECEPTACLES ARE IN USE
APT 5 BATHROOM GFCI OUTLET 110.2
RSLV 04/02/2015 04/02/2015 04/21/2015
 
014 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
APT 28 SUPER APT KO MISSING 110.12
RSLV 04/02/2015 04/02/2015 04/21/2015