BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B378798
Premises: 543 EAST 28 STREET BROOKLYN BIN: 3120986     Block: 5230   Lot: 27
   
Application Completed and Certified

Filed: 543 E 28 ST Census Tract:   788 Health Area:  7410
GROUND FLOOR / BASEMENT Admin Area:   B - BROOKLYN Inspection Area:   K
BROOKLYN, NY 11210 Community Board:   314
Special Place Name:   N/A
DOB Cross Street(s):   FOSTER AVENUE,    FARRAGUT ROAD
Status:   C - JOB IS SIGNED OFF 11/05/2014
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  03/18/2014 4:47 PM
Application Entered:   03/18/2014 Job Start Date:   03/26/2014
Last Change:   11/05/2014 Job End Date:   04/30/2014
Appointment Status:   
Last Inspection By:   DALTON HENLON       On     10/21/2014      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 011368 Licensee Name: CHRISTOPHER J STABILE
Firm: 002791 Firm Name: STABILITY ELEC ENTERP INC
Firm Phone: 718-449-8800  Firm Address: 8762 20TH AVENUE BROOKLYN NY 11214-4804 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $115.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   A - One Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: SYLVA FRANCOIS
Owner Business Name: N/A
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  200A, COMBO MAIN PANEL
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  #3/0 THHN S/E CONDUCTORS
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS  N/A               
Buildings Total                 
Total Units : 7 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 1 + New Meters 1 - Removed Meters 1 = Total Meters 1

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 03/18/2014 Notice:  
Power Issued: 03/18/2014 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  CONTRACTOR #00563 THIS APP. IS FILED FOR 1-NEW, 208V/200A,SGL.-PHASE, OUTDOOR, U/G SERVICE. EXISTING SERVICE IS A 110V/30A, INDOOR, U/G, SYSTEM. THE SCOPE OF WORK INCLUDES: 1-NEW, OUTDOOR, 208V/200A, METER PAN AND 1-NEW, INDOOR, 208V/200A, 30/30CKT. COMBO MAIN DISTRIBUTION PANEL.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B378798
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/21/2014 10/27/2014 DAH C E (20) (0) Y
INSPECTION COMMENTS: N




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.