BIS Menu  |  ECB Violations  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B377648
Premises: 162 27 STREET BROOKLYN BIN: 3009725     Block: 660   Lot: 20
   
Application Completed and Certified

Filed: 162 27 ST Census Tract:   101 Health Area:  4400
BETWEEN 3 AND 4 AVE Admin Area:   B - BROOKLYN Inspection Area:   F
BROOKLYN, NY 11232 Community Board:   307
Special Place Name:   SERVIE & 1 F
DOB Cross Street(s):    3 AVENUE,    4 AVENUE
Status:   C - JOB IS SIGNED OFF 07/30/2014
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  02/14/2014 5:17 PM
Application Entered:   02/14/2014 Job Start Date:   02/15/2014
Last Change:   07/30/2014 Job End Date:   10/15/2014
Appointment Status:   
Last Inspection By:   CAMPBELL, C       On     07/28/2014      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010998 Licensee Name: ARTHUR HABER
Firm: 000634 Firm Name: HABER ELECTRIC CO., INC.
Firm Phone: 718-782-2566  Firm Address: 101 RICHARDSON STREET BROOKLYN NY 11211 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $132.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   B - Two Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MARIA UGARTE
Authorized Representative:  MARIA UGARTE
Relationship To Owner:   OWNER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  3  100
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  3  45
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  45
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001  1 FL  13  12         
Buildings Total 13  12              
Total Units : 42 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 3 #4-Wire 0 #10-Wire 0
Existing Meters 1 + New Meters 3 - Removed Meters 1 = Total Meters 3

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 02/14/2014 Notice: 1 - FIRST NOTICE 06/23/2014
Power Issued: 02/14/2014 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  NEW SERVICE 1ST FLOOR REWIRE

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B377648
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/02/2014 06/09/2014 CCH V E (70) (13) Y
INSPECTION COMMENTS: JOB NOT COMPLETE
 
(2) 06/19/2014 06/23/2014 CJE A R E (30) (2) Y
INSPECTION COMMENTS: N
 
(3) 07/17/2014 07/21/2014 CJH N (30) (0) Y
INSPECTION COMMENTS: N
 
(4) 07/28/2014 07/30/2014 CLC C R E (30) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B377648
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
ALL OUTLETS NOT TAMPER PROOF 406.11
RSLV 06/02/2014 06/02/2014 06/19/2014
 
002 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
SMOKE DETECTOR NO ARC FAULT
RSLV 06/02/2014 06/02/2014 06/19/2014
 
003 ( 35) APPROVED OUTLETS HAVE NOT BEEN PROVIDED FOR AIR CONDITIONERS
NO AC OUTLET LIVING ROOM
RSLV 06/02/2014 06/02/2014 06/19/2014
 
004 ( 16) DEFECTIVE LIGHTING FIXTURES ARE IN USE
PIGTAIL IN US
RSLV 06/02/2014 06/02/2014 06/19/2014
 
005 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
KO MISSING SER SW END BOX
RSLV 06/02/2014 06/02/2014 06/19/2014
 
006 ( 7) EMT IS NOT PROPERLY SUPPORTED (TYPE:EMT)
EMT TO END BOX NO STRAPP
RSLV 06/02/2014 06/02/2014 06/19/2014
 
007 ( 25) ARMORED CABLES ARE NOT PROPERLY TERMINATED
METER NEUTRAL JUMPER NOT PROPER INSTALL ALL METERS
RSLV 06/02/2014 06/02/2014 06/19/2014
 
008 ( 1) SERVICE EQUIPMENT ENCLOSURES ARE NOT BONDED TOGETHER
MIGB MISSING BONDING SCREW
RSLV 06/02/2014 06/02/2014 06/19/2014
 
009 ( 5) SERVICE GROUNDING CONDUCTOR HAS NOT BEEN INSTALLED PROPERLY
GROUND NOT TO NEUTRAL BAR
RSLV 06/02/2014 06/02/2014 06/19/2014
 
010 (999) OTHER
NEUTRAL BAR NOT BONDED 250.28
RSLV 06/02/2014 06/02/2014 06/19/2014
 
011 ( 10) BRANCH CIRCUIT CONDUCTORS ARE NOT PROPER SIZE
20 AMP BREAKER ON OLD #14 WIRE
RSLV 06/02/2014 06/02/2014 06/19/2014
 
012 ( 53) GFCI HAS NOT BEEN PROVIDED
GFCI NOT INSTALLED IN BATHROOM
RSLV 06/02/2014 06/02/2014 06/19/2014
 
013 (999) OTHER
NO GROUNDING TERMINAL INSTALL 250.64 F3
RSLV 06/02/2014 06/02/2014 06/19/2014
 
014 ( 5) SERVICE GROUNDING CONDUCTOR HAS NOT BEEN INSTALLED PROPERLY
G.E.C. NOT CONNECTED TO NEUTRAL BAR IN SERVICE SWITCH ART 250.24(C)
RSLV 06/19/2014 06/19/2014 07/28/2014
 
015 (231) NO OTHER OUTLET
MICROWAVE RECEPTACLE + HOOD CONNECTED TO SMALL APPLIANCE COUNTERTOPCIRCUIT ART.210.52(B2)
RSLV 06/19/2014 06/19/2014 07/28/2014