BIS Menu  |  DOB Violations  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B375628
Premises: 38 PROSPECT PARK WEST BROOKLYN BIN: 3025138     Block: 1075   Lot: 35
   
Application Completed and Certified

Filed: 40 PROSPECT PARK W Census Tract:   165 Health Area:  4500
5B AND 5C Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11215 Community Board:   306
DOB Cross Street(s):   GARFIELD PLACE,    1 STREET
Status:   C - JOB IS SIGNED OFF 07/30/2015
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  12/13/2013 8:31 AM
Application Entered:   12/13/2013 Job Start Date:   12/13/2013
Last Change:   07/30/2015 Job End Date:   03/15/2014
Appointment Status:   
Last Inspection By:   DAMISO COOTE       On     07/28/2015      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010044 Licensee Name: FRANK GAROFALO
Firm: 001825 Firm Name: FRANDAL ELECTRIC CO.
Firm Phone: 718-519-8160  Firm Address: 3601-F BAINBRIDGE AVENUE BRONX NY 10467 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $53.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: SHY ORMSON
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
005  5B/C    22  19  17             
Buildings Total   22  19  17                
Total Units : 62 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 02/09/2015 Notice: 1 - FIRST NOTICE 03/16/2015
Power Issued: 02/09/2015 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B375628
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 07/14/2014 07/21/2014 CJE A (60) (8) Y
INSPECTION COMMENTS: N
 
(2) 02/05/2015 02/09/2015 PAT A R E (30) (1) Y
INSPECTION COMMENTS: PLEASE OPEN PANELS AND CHECK
 
(3) 03/09/2015 03/16/2015 CJH A R E (40) (1) Y
INSPECTION COMMENTS: N
 
(4) 07/28/2015 07/30/2015 DIT C R E (30) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B375628
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 63) RECEPTACLE OUTLETS NOT IN SUFFICIENT NUMBER
KITCHEN - MISSING PENINSULAR COUNTER TOP RECEPTACLE ART 210.52(C3)
RSLV 07/14/2014 07/14/2014 02/05/2015
 
002 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
FOYER CLOSET LIGHTS NOT AFCI. 210.12(B)
RSLV 07/14/2014 07/14/2014 02/05/2015
 
003 (231) NO OTHER OUTLET
MASTER BEDROOMS A/C RECEPTACLE CONNECTED TO BEDROOM LIGHTS + BATHROOM GFCI + CLOSET 210.52(B2)
RSLV 07/14/2014 07/14/2014 02/05/2015
 
004 (999) OTHER
FOYER LIGHTS + 2ND BATHROOM CONNECTED TOGETHER WITH GFCI ART 210.11(C3)
RSLV 07/14/2014 07/14/2014 02/05/2015
 
005 (999) OTHER
MULTIWIRE CIRCUITS MEANS OF DISCONNECTS NOT SIMULTANEOUS. 210.4(B)
RSLV 07/14/2014 07/14/2014 02/05/2015
 
006 (999) OTHER
MULTIWIRE CIRCUITS NOT GROUPED 210.4(D0
RSLV 07/14/2014 07/14/2014 02/05/2015
 
007 (999) OTHER
AFCI INSTALLED NOT LISTED TYPE. 210.12(B)
RSLV 07/14/2014 07/14/2014 02/05/2015
 
008 (999) OTHER
BOTH BATHROOM FIXTURES SUITABLE FOR DRY LOCATION ONLY 410.10(A)
RSLV 07/14/2014 07/14/2014 02/05/2015
 
009 (999) OTHER
RECEPTICLES NOT TAMPER RESISTANCE 406.11
RSLV 02/05/2015 02/05/2015 03/09/2015
 
010 (999) OTHER
APT 5B 5C RECEPTICLES OUTLET OUTSIDE OF PNL CLOSET ZIP SCREW USED250.8
RSLV 03/09/2015 03/09/2015 07/28/2015



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  DOB Violations  |  Electrical Inspection Work Order  |  Back