BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B372399
Premises: 86 LOUISIANA AVENUE BROOKLYN BIN: 3422015     Block: 4317   Lot: 18
   
Application Completed and Certified

Filed: 86 LOUISIANA AV Census Tract:   1098 Health Area:  7520
LOUISIANA AVE Admin Area:   B - BROOKLYN Inspection Area:   L
BROOKLYN, NY 11207 Community Board:   305
Related Job Number:    320377711
DOB Cross Street(s):   LINDEN BOULEVARD,    DE WITT AVENUE
Status:   C - JOB IS SIGNED OFF 05/28/2014
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  09/15/2013 8:55 PM
Application Entered:   09/15/2013 Job Start Date:   09/17/2013
Last Change:   05/28/2014 Job End Date:   02/17/2014
Appointment Status:   
Last Inspection By:   CHARLES COURTNEY       On     05/06/2014      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 012077 Licensee Name: STEVEN L BOODHOO
Firm: 003766 Firm Name: K.A.B. ELECTRIC CORP
Firm Phone: 718-454-5464  Firm Address: 212-27 JAMAICA AVENUE QUEENS VILLAGE NY 11428 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $170.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   B - Two Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MATTHEW ADHOOT
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  3  THREE 60 AMP SWITCHES
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  ONE SET #2 AWG
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  3  THREE PANELS
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS      12               
001      25  12  16             
002      25  12  16             
003      25  12  16             
Buildings Total   87  42  56                
Total Units : 194 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 3 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 3 - Removed Meters 0 = Total Meters 3

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 09/15/2013 Notice:  
Power Issued: 09/15/2013 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B372399
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/06/2014 05/13/2014 CCH C E (60) (0) Y
INSPECTION COMMENTS: N




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.