NYC Department of Buildings
Electrical Application Details for App #: B369065
Premises: 383 STATE STREET BROOKLYN BIN: 3000567     Block: 172   Lot: 55
   
Application Completed and Certified

Filed: 383 STATE ST Census Tract:   41 Health Area:  2400
BASEMENT Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11217 Community Board:   302
Special Place Name:   PS 369K
DOB Cross Street(s):   BOND STREET,    NEVINS STREET
Status:   C - JOB IS SIGNED OFF 12/10/2013
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  06/13/2013 6:53 PM
Application Entered:   06/13/2013 Job Start Date:   07/01/2013
Last Change:   12/10/2013 Job End Date:   07/01/2014
Appointment Status:   
Last Inspection By:   BANYA, E       On     12/02/2013      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 011515 Licensee Name: ESSAM HANNA
Firm: 003943 Firm Name: COMMERCE ELECL CONTRG COR
Firm Phone: 718-233-4955  Firm Address: 23-86 BQE WEST SUITE 201 ASTORIA NY 11103 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $128.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   W - School
Special Cert Approval:   L - FIRE ALARM LOCAL LAW #5
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MARIA GOMEZ
Owner Business Name: NYC SCA
Authorized Representative:  MARIA GOMEZ
Relationship To Owner:   REPRESENTATIVE


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  60 AMP 4-WIRE
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  2  5#8 IN 1-1/4"C
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  12 CKT. FUSED CUT OUT
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS                       
001                       
002                       
003                       
Buildings Total                       
Total Units : 9 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  WIRING FOR FIRE ALARM SYSTEM,PRINTER AND BOOSTER POWER SUPPLIES.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B369065
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/02/2013 12/10/2013 EBA C (30) (0) Y
INSPECTION COMMENTS: N