| BUILDING OVERVIEW |
Are Feeders Being Installed? : No |
| (If feeders are being installed, provide a wiring diagram and calculations at the time of inspection) |
| Building Overview Work Items |
QUANTITY |
DESCRIPTION |
| SERVICE SWITCHES |
|
| A. Up to 100 AMPS |
0 |
|
| B. 101 Up to 200 AMPS |
0 |
|
| C. 201 Up to 600 AMPS |
0 |
|
| D. 601 Up to 1200 AMPS |
0 |
|
| E. Over 1200 AMPS |
0 |
|
| SER. ENT. & FDR COND (EACH SET) |
|
| A. Up to #2 CONDUCTOR |
0 |
|
| B. Over #2 to 1/0 |
0 |
|
| C. Over 1/0 to 250 MCM |
0 |
|
| D. Over 250 MCM |
0 |
|
| PANELS |
|
| A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs |
0 |
|
| B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs |
0 |
|
| C. 3 Phase Up to 225 AMPS |
4 |
|
| D. 3 Phase Over 225 AMPS |
0 |
|
| ELEVATORS / ESCALATORS / MATERIAL LIFTS |
|
| A. Total No. of Elevators / Escalators / Material Lifts |
0 |
|
| B. Each Additional 10 Floors Or Less |
0 |
|
| BOILER CONTROLS |
0 |
|
| OBJECTION ID |
OBJECTION CODE |
OBJECTION DESCRIPTION & COMMENTS |
STAT |
FIRST |
LATEST |
RESLVD |
| |
| 001 |
(999) |
OTHER EMT INSTALLED INSIDE COOKING HOOD 410.10(C4) |
RSLV |
09/05/2013 |
09/05/2013 |
10/24/2013 |
| |
| 002 |
(999) |
OTHER AMORED CABLE (BX) EXPOSED IN WALK INBOX 330.12 |
RSLV |
09/05/2013 |
09/05/2013 |
10/24/2013 |
| |
| 003 |
(999) |
OTHER ROMEX CABLE EXPOSED IN WALK IN BOX334.12(B4) |
RSLV |
09/05/2013 |
09/05/2013 |
10/24/2013 |
| |
| 004 |
(999) |
OTHER ENCLOSURE THROUGH OUT FOR OUTSIDE GFCI NOTWEATHER RESISTANCE 406.8(B1) |
RSLV |
09/05/2013 |
09/05/2013 |
10/24/2013 |
| |
| 005 |
(999) |
OTHER MULTIWIRE CIRCUITS IN ALL PANELS MEANS OF DISCONNECTNOT SIMULTANEOUS 210.4 |
RSLV |
09/05/2013 |
09/05/2013 |
10/24/2013 |
| |
| 006 |
(328) |
CIRCUIT CONDUCTORS NOT GROUPED CIRCUIT CONDUCTOR NOT GROUPED 300.20 |
RSLV |
09/05/2013 |
09/05/2013 |
10/24/2013 |
| |
| 007 |
(315) |
CONDUCTORS NOT PROPERLY IDENTIFIED EQUIPMENT GROUND FOR A/C NOT IDENTIFIED 200.6 |
RSLV |
09/05/2013 |
09/05/2013 |
10/24/2013 |
| |
| 008 |
(243) |
CONDUCTORS OF THE SAME CIRCUIT NOT GROUPED CONDUCTOR NOT GROUPED 300.3 |
RSLV |
09/05/2013 |
09/05/2013 |
10/24/2013 |
| |
| 009 |
(307) |
NO RECEPTACLE OUTLET WITHIN 25 FEET FOR HVAC EQUIPMENT NO RECEPTACLE INSTALLED 210.63 |
RSLV |
09/05/2013 |
09/05/2013 |
10/24/2013 |
| |
| 010 |
( 16) |
DEFECTIVE LIGHTING FIXTURES ARE IN USE ROOF BAR SER/RM NOT COMPLETED PIGTAIL |
RSLV |
10/24/2013 |
10/24/2013 |
11/14/2013 |
| |
| 011 |
(999) |
OTHER ROOF NEAR AC GFCI NOT W/R 406.8 |
RSLV |
10/24/2013 |
10/24/2013 |
11/14/2013 |
| |
| 012 |
( 19) |
DEFECTIVE WIRING IS IN USE ROOF NEAR AC GFCI TAP OF AC DIS SW |
RSLV |
10/24/2013 |
10/24/2013 |
11/14/2013 |