BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B361494
Premises: 1398 NOSTRAND AVENUE BROOKLYN BIN: 3116823     Block: 5088   Lot: 39
   
Application Completed and Certified

Filed: 1398 NOSTRAND AV Census Tract:   820 Health Area:  5400
01 FL Admin Area:   B - BROOKLYN Inspection Area:   G
BROOKLYN, NY 11226 Community Board:   317
DOB Cross Street(s):   LINDEN BOULEVARD,    MARTENSE STREET
Status:   C - JOB IS SIGNED OFF 11/16/2015
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  02/08/2013 7:21 PM
Application Entered:   02/08/2013 Job Start Date:   02/11/2013
Last Change:   11/16/2015 Job End Date:   02/28/2013
Appointment Status:   
Last Inspection By:   THOMAS, PATRICIA       On     09/14/2015      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 012093 Licensee Name: MUHAMMAD MUNIR
Firm: 003789 Firm Name: MAGIC ELECTRIC INC
Firm Phone: 917-755-1300  Firm Address: 150-35 HILLSIDE AVE JAMAICA NY 11432 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $63.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Commercial/Residential (1  Stores, 6 Apartments)
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: ABDUL RAZIQ
Owner Business Name: N/A
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  100 AMP SW
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  # 2 WIRE
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 7 + New Meters 1 - Removed Meters 0 = Total Meters 8

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 02/08/2013 Notice: 1 - FIRST NOTICE 09/08/2014
Power Issued: 02/08/2013 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  SERVICE WORK

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B361494
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/04/2014 09/08/2014 CCH A E (60) (1) Y
INSPECTION COMMENTS: 1 METER & 1 PANEL BASEMENT
 
(2) 09/30/2014 10/14/2014 CLC N (60) (0) Y
INSPECTION COMMENTS: NO ACCESS
 
(3) 09/14/2015 09/21/2015 PAT C R E (35) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B361494
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
BASEMENT ELECTRICIAL REM LIGHT ON NEW METER 210.25
RSLV 09/04/2014 09/04/2014 09/14/2015



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order