BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B360807
Premises: 945 PARK PLACE BROOKLYN BIN: 3031306     Block: 1235   Lot: 70
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 945 PARK PL Census Tract:   341 Health Area:  4900
BASEMENT, 1FL,2FL,3FL,4FL Admin Area:   B - BROOKLYN Inspection Area:   G
BROOKLYN, NY 11213 Community Board:   308
Related Job Number:    320552772
DOB Cross Street(s):   NEW YORK AVENUE,    BROOKLYN AVENUE
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  02/03/2013 4:41 PM
Application Entered:   02/03/2013 Job Start Date:   02/04/2013
Last Change:   08/22/2025 Job End Date:   02/01/2014
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   JOHN, CHARLES       On     09/12/2014      
Field Disp:   N - NO ACCESS
Energize Recommendation:  
Objection Disposition:  

License #: 011485 Licensee Name: BENJAMIN DREBIN
Firm: 002950 Firm Name: ACCURATE ELEC'L CORP.
Firm Phone: 718-606-9181  Firm Address: 11-07 43RD ROAD LONG ISLAND CITY NY 11101 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $1,194.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:   B - BOILER CONTROLS J-51 CERTIFICATION
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MATT KATZ
Owner Business Name: 945 PARK PL LLC
Authorized Representative:  MATT KATZ
Relationship To Owner:   MANAGEMENT


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  17  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  17  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  2  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  17  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  1  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS  BAS  10  10    10  10             
001  1FL  40  100  14  40  40             
002  2FL  40  100  14  40  40             
003  3FL  40  100  14  40  40             
004  4FL  40  100  14  40  40             
Buildings Total 170  410  56  170  170                
Total Units : 976 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 17 #4-Wire 0 #10-Wire 0
Existing Meters 17 + New Meters 17 - Removed Meters 17 = Total Meters 17

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 02/03/2013 Notice:  
Power Issued: 02/03/2013 Response:  

Follow-Up:
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B360807
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/12/2014 09/15/2014 CJH N (15) (0) Y
INSPECTION COMMENTS: N




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.