Premises: 308 7 STREET BROOKLYN BIN: 3021855     Block: 998   Lot: 32
   
Application Completed and Certified

Filed: 308 SEVENTH ST Census Tract:   137 Health Area:  4600
ENTIRE Admin Area:   B - BROOKLYN Inspection Area:   F
BROOKLYN, NY 11215 Community Board:   306
DOB Cross Street(s):    4 AVENUE,    5 AVENUE
Status:   C - JOB IS SIGNED OFF 06/18/2013
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  10/12/2012 9:31 AM
Application Entered:   10/12/2012 Job Start Date:   10/12/2012
Last Change:   06/18/2013 Job End Date:   08/05/2013
Appointment Status:   
Last Inspection By:   BANYA, E       On     06/12/2013      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010438 Licensee Name: SILVIO HONOVIC
Firm: 000244 Firm Name: BLUE RIBBON ELEC'L CONTRS
Firm Phone: 718-625-5000  Firm Address: 500 SMITH STREET BROOKLYN NY 11231 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
7 - HVAC WIRING
Total Fee:  $231.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   B - Two Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: RESIDENCE SCHENKER
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  100 AMP SINGLE PHASE
B. 101 Up to 200 AMPS  1  150 AMP SINGLE PHASE
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  3 #2 WIRES
B. Over #2 to 1/0  1  3 1/0 CONDUCTORS
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  100 AMP SINGLE PHASE
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  150 AMP SINGLE PHASE
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL                 
GND    19  14  29             
001    12  15             
002    15  12  21             
Buildings Total 13  55  47  65                
Total Units : 184 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 2 #4-Wire 0 #10-Wire 0
Existing Meters 2 + New Meters 2 - Removed Meters 2 = Total Meters 2

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 10/12/2012 Notice: 1 - FIRST NOTICE 05/02/2013
Power Issued: 10/12/2012 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B354957
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 04/22/2013 05/02/2013 CJH A E (65) (8) Y
INSPECTION COMMENTS: N
 
(2) 06/12/2013 06/18/2013 EBA C R E (30) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B354957
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
NO COLLECTIVE BUS BAR PROVIDED 250.64 (F3)
RSLV 04/22/2013 04/22/2013 06/12/2013
 
002 ( 1) SERVICE EQUIPMENT ENCLOSURES ARE NOT BONDED TOGETHER
100A SWITCH BONDED SCREW MISSING 250.92A
RSLV 04/22/2013 04/22/2013 06/12/2013
 
003 (999) OTHER
GFCI REAR FRONT BSMT ROOF NOT LISTED TR/WR 406.8
RSLV 04/22/2013 04/22/2013 06/12/2013
 
004 (999) OTHER
1ST 2ND FL BATHROOM DOUBLE SINK GFCI IN CLOSE CABINET 210.52 (D)
RSLV 04/22/2013 04/22/2013 06/12/2013
 
005 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
ALL PANEL GRN CONDUCTOR NOT TERMINATED 250.122
RSLV 04/22/2013 04/22/2013 06/12/2013
 
006 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
2ND FL BEDROOMS BREAKERS NOT LISTED COMBO TYPE 210.12B
RSLV 04/22/2013 04/22/2013 06/12/2013
 
007 (315) CONDUCTORS NOT PROPERLY IDENTIFIED
ROOF AC UNITS BLK CONDUCTORS TAPE GRN 200.6
RSLV 04/22/2013 04/22/2013 06/12/2013
 
008 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
ALL PANEL 110.12 (A)
RSLV 04/22/2013 04/22/2013 06/12/2013