| NYC Department of Buildings | ||
| Electrical Application Details for App #: B352611 | ||
| Premises: 1257 EAST 18 STREET BROOKLYN | BIN: 3180714 Block: 6738 Lot: 74 |
| Application Completed and Certified | ||
| Filed: | 1257 E 18 ST | Census Tract: 538 | ||
| WHOLE HOUSE | Admin Area: B - BROOKLYN | Inspection Area: K | ||
| BROOKLYN, NY 11230 | Community Board: 314 | |||
| DOB Cross Street(s): AVENUE L, BAY AVENUE | |||
| Status: C - JOB IS SIGNED OFF 05/13/2013 | |||
| Request Type: A - APPLICATION | eFiled: YES | Permit Issued: 08/01/2012 2:53 PM | |
| Application Entered: 08/01/2012 | Job Start Date: 08/01/2012 | ||
| Last Change: 05/13/2013 | Job End Date: 08/01/2012 | ||
| Appointment Status: | |||
| Last Inspection By: DOYLEY, DEXTER On 05/10/2013 | |||
| Field Disp: C - INSPECTION PASSED | |||
| Energize Recommendation: E - ISSUE POWER AUTH | |||
| Objection Disposition: R - REMOVED | |||
| License #: | 012418 | Licensee Name: | ELVIS FERNANDEZ | |
| Firm: | 004209 | Firm Name: | FERCO ELECTRIC SERVICE CO | |
| Firm Phone: | 718-651-7490 | Firm Address: | 53-14 ROOSEVELT AVE WOODSIDE NY 11377 | |
| Work Started or Filed by Others: NO | ||||||||
| Work Category: R - REHABILITATION | Work To Be Done:
1 - SERVICE WORK/NOTIFY UTILITY 6 - GENERAL WIRING |
Total Fee: $344.25 | ||||||
| Other Work: | ||||||||
| Work Related to a New or Amended Certificate of Occupancy: NO | ||||||||
| This Job Regulated by the NYC Energy Conservation Code: No | ||||||||
| Building Used As: L - Five Or More Family | |||||||
| Special Cert Approval: | |||||||
| Advisory Board Approval: NOT APPLICABLE | |||||||
| Owner / Occup: | RACHEL TSATSKIS | ||||||
| Owner Business Name: | TSATSKIS | ||||||
| Authorized Representative: | |||||||
| Relationship To Owner: | |||||||
|
|
| Floor | Apt. | Number Of Outlets | No. Of Fixtures |
Motors / Generators | Heaters | Transformers | ||||||
| Fixt | Receptacles | Switch | Num | Total HP KW | Num | Total KW | Num | Total KVA | ||||
| ATT | A/C | |||||||||||
| GND | 5 | 7 | 20 | 2 | 6 | |||||||
| 001 | A | 6 | 18 | 2 | 6 | |||||||
| 001 | B | 6 | 22 | 3 | 7 | |||||||
| 002 | A | 6 | 18 | 2 | 6 | |||||||
| 002 | B | 6 | 22 | 3 | 7 | |||||||
| Buildings Total | 31 | 100 | 12 | 32 | ||||||||
| Total Units : 175 units | ||||||||||||
| Signs: | Field Connect: | 0 | Field Inspect: | 0 | Tags: | ||
| Meter Request to Utility | #3-Wire | 6 | #4-Wire | 0 | #10-Wire | 0 | |
| Existing Meters | 5 | + New Meters | 6 | - Removed Meters | 5 | = Total Meters | 6 |
| Power Auth Flag: | I - ISSUED | Objection Flag: | |
| Power Requested: | 08/01/2012 | Notice: | 1 - FIRST NOTICE 04/30/2013 |
| Power Issued: | 08/01/2012 | Response: |
| Follow-Up: | K - (CLOSED) | ||
| Contractor's Comments: RESUBMITTAL OF APPLICATION B352136, UNFORTUNATELY WHEN SUBMITTED SEVERAL MISTAKES WERE POINTED OUT. AND I WAS ADVISED TO REFILE WITH THE CORRECTIONS. THE AMENDMENT REQUEST I WASTOLD IS NOT CURRENTLY WORKING. I WILL BE INSTALLING 6 METERS 1 FOR EACH APT. 1 FOR PLP. | |||
|
|