| NYC Department of Buildings | ||
| Electrical Application Details for App #: B346643 | ||
| Premises: 235 CARLTON AVENUE BROOKLYN | BIN: 3397436 Block: 2090 Lot: 17 |
| Application Completed and Certified | ||
| Filed: | 237 CARLTON AV | Census Tract: 183 | Health Area: 1200 | |
| BASEMENT,1,2,3,4 FLOOR | Admin Area: B - BROOKLYN | Inspection Area: D | ||
| BROOKLYN, NY 11205 | Community Board: 302 | |||
| DOB Cross Street(s): WILLOUGHBY AVENUE, DEKALB AVENUE | |||
| Status: C - JOB IS SIGNED OFF 01/22/2013 | |||
| Request Type: A - APPLICATION | eFiled: YES | Permit Issued: 01/25/2012 7:17 PM | |
| Application Entered: 01/25/2012 | Job Start Date: 01/26/2012 | ||
| Last Change: 01/22/2013 | Job End Date: 08/20/2012 | ||
| Appointment Status: | |||
| Last Inspection By: ASHMAN, K. On 12/10/2012 | |||
| Field Disp: C - INSPECTION PASSED | |||
| Energize Recommendation: E - ISSUE POWER AUTH | |||
| Objection Disposition: | |||
| License #: | 011511 | Licensee Name: | EUSEBIO E MCQUEEN | |
| Firm: | 002982 | Firm Name: | RM ELECTRIC CO., INC. | |
| Firm Phone: | 718-272-0065 | Firm Address: | 240 KENT AVE, SUITE KB/22C BROOKLYN NY 11249 | |
| Work Started or Filed by Others: NO | ||||||||
| Work Category: R - REHABILITATION | Work To Be Done:
1 - SERVICE WORK/NOTIFY UTILITY 6 - GENERAL WIRING |
Total Fee: $307.75 | ||||||
| Other Work: | ||||||||
| Work Related to a New or Amended Certificate of Occupancy: NO | ||||||||
| This Job Regulated by the NYC Energy Conservation Code: No | ||||||||
| Building Used As: A - One Family | |||||||
| Special Cert Approval: | |||||||
| Advisory Board Approval: NOT APPLICABLE | |||||||
| Owner / Occup: | MICHAEL LASKAWY | ||||||
| Authorized Representative: | |||||||
| Relationship To Owner: | |||||||
|
|
| Floor | Apt. | Number Of Outlets | No. Of Fixtures |
Motors / Generators | Heaters | Transformers | ||||||
| Fixt | Receptacles | Switch | Num | Total HP KW | Num | Total KW | Num | Total KVA | ||||
| ATT | A/C | |||||||||||
| GND | 10 | 25 | 10 | 1 | 2 | |||||||
| MZ1 | 10 | 22 | 10 | 1 | 2 | |||||||
| MZ2 | 10 | 20 | 10 | 1 | 2 | |||||||
| MZ3 | 10 | 20 | 10 | 1 | 2 | |||||||
| MZ4 | 6 | 20 | 6 | 1 | 2 | |||||||
| Buildings Total | 46 | 107 | 46 | 10 | ||||||||
| Total Units : 209 units | ||||||||||||
| Signs: | Field Connect: | 0 | Field Inspect: | 0 | Tags: | ||
| Meter Request to Utility | #3-Wire | 1 | #4-Wire | 0 | #10-Wire | 0 | |
| Existing Meters | 1 | + New Meters | 1 | - Removed Meters | 1 | = Total Meters | 1 |
| Power Auth Flag: | I - ISSUED | Objection Flag: | |
| Power Requested: | 01/25/2012 | Notice: | |
| Power Issued: | 01/25/2012 | Response: |
| Follow-Up: | K - (CLOSED) | ||
| Contractor's Comments: PARCIAL WIRING, SMOKE DETECTOR AND CARBON MONOXIDE BEEN INSTALLED | |||
|
|