BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B346449
Premises: 554 LAFAYETTE AVENUE BROOKLYN BIN: 3049882     Block: 1788   Lot: 37
   
Application Completed and Certified

Filed: 554 LAFAYETTE AV Census Tract:   243 Health Area:  2800
BASEMENT Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11205 Community Board:   303
DOB Cross Street(s):   BEDFORD AVENUE,    NOSTRAND AVENUE
Status:   C - JOB IS SIGNED OFF 05/03/2012
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  01/18/2012 11:58 PM
Application Entered:   01/18/2012 Job Start Date:   01/19/2012
Last Change:   05/03/2012 Job End Date:   01/15/2013
Appointment Status:   
Last Inspection By:   DOYLEY, DEXTER       On     03/21/2012      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 012355 Licensee Name: PETER MILEVSKI
Firm: 003361 Firm Name: ELMAC ELECTRIC INC.
Firm Phone: 718-894-9727  Firm Address: 97-77 QUEENS BLVD TOWER FLOOR REGO PARK NY 11374 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $132.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: PATRICK CHAN
Authorized Representative:  PATRICK CHAN
Relationship To Owner:   OWNER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  4  1 PH. 60A
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  4  3 # 3; 3 # 6
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 4 #4-Wire 0 #10-Wire 0
Existing Meters 3 + New Meters 4 - Removed Meters 3 = Total Meters 4

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 01/18/2012 Notice:  
Power Issued: 01/18/2012 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  WORK ON ELECTRIC SERVICE IN BASEMENT ONLY.RECONNECT THE EXISTING FEEDERS AND BRANC CIRCUITS TO NEW SERVICE METERS.NO WORK IN APARTMENTS, BASEMENT AND HALLWAYS

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B346449
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/21/2012 04/10/2012 DEX C E (30) (0) Y
INSPECTION COMMENTS: N




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back