| NYC Department of Buildings | ||
| Electrical Application Details for App #: B346358 | ||
| Premises: 1208 AVENUE R BROOKLYN | BIN: 3183891 Block: 6818 Lot: 4 |
| Application Completed and Certified | ||
| Filed: | 1208 AV R | Census Tract: 556 | Health Area: 8710 | |
| 1ST,2ND,BSMT | Admin Area: B - BROOKLYN | Inspection Area: P | ||
| BROOKLYN, NY 11229 | Community Board: 315 | |||
| DOB Cross Street(s): EAST 12 STREET, EAST 13 STREET | |||
| Status: C - JOB IS SIGNED OFF 05/29/2012 | |||
| Request Type: A - APPLICATION | eFiled: YES | Permit Issued: 01/16/2012 8:17 PM | |
| Application Entered: 01/16/2012 | Job Start Date: 01/18/2012 | ||
| Last Change: 05/29/2012 | Job End Date: 06/29/2012 | ||
| Appointment Status: | |||
| Last Inspection By: ROBINSON HEATH On 05/21/2012 | |||
| Field Disp: C - INSPECTION PASSED | |||
| Energize Recommendation: E - ISSUE POWER AUTH | |||
| Objection Disposition: | |||
| License #: | 012281 | Licensee Name: | WINSTON CUMMINS | |
| Firm: | 004047 | Firm Name: | WORD OF LIGHT ELECT LLC | |
| Firm Phone: | 718-210-3336 | Firm Address: | 224-02 LINDEN BLVD CAMBRIA HEIGHTS NY 11411 | |
| Work Started or Filed by Others: NO | ||||||||
| Work Category: R - REHABILITATION | Work To Be Done:
1 - SERVICE WORK/NOTIFY UTILITY 6 - GENERAL WIRING |
Total Fee: $193.75 | ||||||
| Other Work: | ||||||||
| Work Related to a New or Amended Certificate of Occupancy: NO | ||||||||
| This Job Regulated by the NYC Energy Conservation Code: No | ||||||||
| Building Used As: A - One Family | |||||||
| Special Cert Approval: | |||||||
| Advisory Board Approval: NOT APPLICABLE | |||||||
| Owner / Occup: | BILL BRIDBORD | ||||||
| Owner Business Name: | NONE | ||||||
| Authorized Representative: | |||||||
| Relationship To Owner: | |||||||
|
|
| Floor | Apt. | Number Of Outlets | No. Of Fixtures |
Motors / Generators | Heaters | Transformers | ||||||
| Fixt | Receptacles | Switch | Num | Total HP KW | Num | Total KW | Num | Total KVA | ||||
| ATT | A/C | |||||||||||
| BAS | 6 | 4 | 6 | 1 | 2 | |||||||
| 001 | 18 | 22 | 18 | 4 | 1 | 2 | ||||||
| 002 | 8 | 14 | 8 | 3 | ||||||||
| Buildings Total | 32 | 40 | 32 | 7 | 4 | |||||||
| Total Units : 115 units | ||||||||||||
| Signs: | Field Connect: | 0 | Field Inspect: | 0 | Tags: | ||
| Meter Request to Utility | #3-Wire | 1 | #4-Wire | 0 | #10-Wire | 0 | |
| Existing Meters | 1 | + New Meters | 1 | - Removed Meters | 1 | = Total Meters | 1 |
| Power Auth Flag: | I - ISSUED | Objection Flag: | |
| Power Requested: | 01/16/2012 | Notice: | |
| Power Issued: | 01/16/2012 | Response: |
| Follow-Up: | K - (CLOSED) | ||
| Contractor's Comments: UPGRADE AND ADD CENTRAL AC | |||
|
|
| INSP ID |
FIELD DATE |
DISP DATE |
INSP ID |
FLD DISP |
OBJ DISP |
ENRG REC |
TIME INSP |
REINSP DATE |
NEW OBJ |
APPT FLAG |
| (1) | 05/21/2012 | 05/29/2012 | HRB | C | E | (70) | (0) | Y | ||
| INSPECTION COMMENTS: | N | |||||||||