Electrical Application Details for App #: B345892
Premises: 72 MAUJER STREET BROOKLYN BIN: 3069670     Block: 2792   Lot: 15
   
Application Completed and Certified

Filed: 72 MAUJER ST Census Tract:   503 Health Area:  0700
ENTIRE BUILDING Admin Area:   B - BROOKLYN Inspection Area:   A
BROOKLYN, NY 11206 Community Board:   301
Related Job Number:    320373029
DOB Cross Street(s):   LORIMER STREET,    LEONARD STREET
Status:   C - JOB IS SIGNED OFF 12/11/2012
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  12/28/2011 10:59 PM
Application Entered:   12/28/2011 Job Start Date:   12/28/2011
Last Change:   12/11/2012 Job End Date:   12/20/2012
Appointment Status:   
Last Inspection By:   JOHN, CHARLES       On     12/04/2012      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 012311 Licensee Name: MOSES ROSENBERGER
Firm: 004090 Firm Name: HIVOLTS ELECTRICAL INC
Firm Phone: 718-855-4346  Firm Address: 21 HERKIMER PLACE BROOKLYN NY 11216 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
7 - HVAC WIRING
Total Fee:  $512.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: LEONARD TERRACE LLC
Authorized Representative:  DAVIV TABAK
Relationship To Owner:   PARTNER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  8  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  1  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  8  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS    12  18    12         
001    12  18    12         
002    12  18    12         
003             
Buildings Total 42  63    32  42              
Total Units : 187 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 8 #4-Wire 0 #10-Wire 0
Existing Meters 8 + New Meters 8 - Removed Meters 8 = Total Meters 8

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 12/28/2011 Notice: 1 - FIRST NOTICE 11/16/2012
Power Issued: 12/28/2011 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  THIS JOB IS TO USE NYC2007 ELECTRICAL CODE

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B345892
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/13/2012 09/17/2012 CJH A E (120) (7) Y
INSPECTION COMMENTS: N
 
(2) 11/14/2012 11/16/2012 CCH V R D (70) (2) Y
INSPECTION COMMENTS: NOTE ADD 7 APT NO UNDER COUNTER LIGHT INSTALLED CABLE BOXES HANGING
 
(3) 12/04/2012 12/10/2012 CJH C R E (5) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B345892
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (282) MINIMUM NUMBER OF SMALL APPLIANCE CIRCUITS
TWO SMALL APPLIANCES CIRCUITS NOT PROVIDED FOR KITCHEN THROUGHOUT210.52 B1
RSLV 09/13/2012 09/13/2012 11/14/2012
 
002 ( 18) DEFECTIVE RECEPTACLES ARE IN USE
THROUGHOUT DISHWASHER OUTLETS NOT WORKING 110.2A
RSLV 09/13/2012 09/13/2012 11/14/2012
 
003 ( 53) GFCI HAS NOT BEEN PROVIDED
SWITCHES BY BASTHROOM SINK NOT GFCI PROTECTED 210.8
RSLV 09/13/2012 09/13/2012 11/14/2012
 
004 ( 1) SERVICE EQUIPMENT ENCLOSURES ARE NOT BONDED TOGETHER
400A SERVICE SWITCH 250.92A
RSLV 09/13/2012 09/13/2012 11/14/2012
 
005 ( 19) DEFECTIVE WIRING IS IN USE
DISCONNECT SWITCHES #10 UNIT CONDUCTORS USED FOR LINE VOLTAGE 110.2A
RSLV 09/13/2012 09/13/2012 11/14/2012
 
006 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
NO DIRECTORY CAR PANEL THROUGHOUT 408.4
RSLV 09/13/2012 09/13/2012 11/14/2012
 
007 ( 36) CONDUCTORS ARE NOT PROPERLY COLOR CODED
SPLICE BOX GREEN CONDUCTORS SPLICE WITH RED CONDUCTOR 210-5
RSLV 09/13/2012 09/13/2012 11/14/2012
 
008 ( 14) CIRCUIT OVERCURRENT PROTECTION DEVICE IS OF IMPROPER SIZE
ALL APT NEED 40 AMP BREAKER FOR STOVE
RSLV 11/14/2012 11/14/2012 12/04/2012
 
009 ( 10) BRANCH CIRCUIT CONDUCTORS ARE NOT PROPER SIZE
KITCHEN ALL APT STOVE NEED #8WIRE FOR STOVE
RSLV 11/14/2012 11/14/2012 12/04/2012