BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B345449
Premises: 289 UNION STREET BROOKLYN BIN: 3397875     Block: 339   Lot: 144
   
Application Completed and Certified

Filed: 289 UNION ST Census Tract:   67 Health Area:  4000
ALL Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11231 Community Board:   306
Related Job Number:    320022104
DOB Cross Street(s):   CLINTON STREET,    COURT STREET
Status:   C - JOB IS SIGNED OFF 07/17/2014
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  12/16/2011 9:23 AM
Application Entered:   12/16/2011 Job Start Date:   12/26/2011
Last Change:   07/17/2014 Job End Date:   12/20/2013
Appointment Status:   
Last Inspection By:   ROBINSON HEATH       On     07/08/2014      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 011006 Licensee Name: YURY LESHCHINSKY
Firm: 003700 Firm Name: ENTERPRISE ELEC'L SYSTEMS
Firm Phone: 718-484-2151  Firm Address: 502 CONEY ISLAND AVE INC BROOKLYN NY 11218 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $409.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   B - Two Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: KENNETH HORN
Owner Business Name: ALCHEMY PROPERTIES
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  2  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  1  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  2  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  3  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL             
BAS    17  23    12  17             
GND    16  19    16             
002    14  14    14             
003    16  14    14  16             
ROF      12         
Buildings Total 71  76    51  71     15           
Total Units : 284 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 3 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 3 - Removed Meters 0 = Total Meters 3

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 12/16/2011 Notice:  
Power Issued: 12/16/2011 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  THIS JOB IS TO USE NYC 2007 ELECTRICAL CODE

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B345449
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 07/08/2014 07/17/2014 HRB C E (40) (0) Y
INSPECTION COMMENTS: N




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order