Electrical Application Details for App #: B344527
Premises: 27 YORK STREET BROOKLYN BIN: 3388734     Block: 45   Lot: 7501
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 70 WASHINGTON ST Census Tract:   21 Health Area:  1000
GROUND FLOOR Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11201 Community Board:   302
DOB Cross Street(s):   FRONT STREET,    YORK STREET
Status:   C - JOB IS SIGNED OFF 07/20/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  11/17/2011 1:04 PM
Application Entered:   11/17/2011 Job Start Date:   11/17/2011
Last Change:   07/20/2016 Job End Date:   11/17/2012
Appointment Status:   
Last Inspection By:   JEFFERSON, CHARLES       On     07/19/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012022 Licensee Name: JOSEPH SORTINO
Firm: 003742 Firm Name: TOP SHELF ELECTRIC CORP
Firm Phone: 718-815-1700  Firm Address: 3917 AMBOY ROAD STATEN ISLAND NY 10308 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
W - SIDEWALK SHED WIRING & LIGHTING
Total Fee:  $52.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Other
Store / Other:   SIDEWALK SHED
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: EVEREST SCAFFOLDING INC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
SWK        56             
Buildings Total     56                
Total Units : 58 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 02/25/2013
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  SIDEWALK SHED

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B344527
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/20/2013 02/25/2013 HRB V (25) (8) Y
INSPECTION COMMENTS: SHED STILL UP
 
(2) 07/19/2016 07/20/2016 CJE C R (19) (0)
INSPECTION COMMENTS: SHED POWER AND LIGHTING REMOVED BEFORE REINSPECTION.

OBJECTION FOR APPLICATION #: B344527
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 19) DEFECTIVE WIRING IS IN USE
(ALL FLOORS) OPEN SPLICE IN BSMT 14/2 ROMEX TO 12/2 ROMEX
RSLV 02/20/2013 02/20/2013 07/19/2016
 
002 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
(ALL FLOORS) USING 14/2 ROMEX SPLICED TO #12/2 ROMEX
RSLV 02/20/2013 02/20/2013 07/19/2016
 
003 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
(ALL FLOORS) NO BOND FOR SHED
RSLV 02/20/2013 02/20/2013 07/19/2016
 
004 ( 5) SERVICE GROUNDING CONDUCTOR HAS NOT BEEN INSTALLED PROPERLY
(ALL FLOORS) NO GROUND FOR SHED
RSLV 02/20/2013 02/20/2013 07/19/2016
 
005 ( 53) GFCI HAS NOT BEEN PROVIDED
(ALL FLOORS) NO GFI PROTECTION FOR SHED
RSLV 02/20/2013 02/20/2013 07/19/2016
 
006 ( 19) DEFECTIVE WIRING IS IN USE
(ALL FLOORS)ROMEX RAN THROUGH ALUMINUM PIPE FROM INSIDE BUILDING TO SHED
RSLV 02/20/2013 02/20/2013 07/19/2016
 
007 ( 8) CONDUIT IS NOT PROPERLY SUPPORTED (TYPE:IMC)
(ALL FLOORS) CONDUIT NOT SUPPORTED PROPERLY OUTSIDE ON SHED
RSLV 02/20/2013 02/20/2013 07/19/2016
 
008 ( 18) DEFECTIVE RECEPTACLES ARE IN USE
(ALL FLOORS) SIDEWALK SHED FEED FROM OUTLETS IN BSMT
RSLV 02/20/2013 02/20/2013 07/19/2016