Electrical Application Details for App #: B343842
Premises: 161 BROADWAY BROOKLYN BIN: 3063558     Block: 2457   Lot: 28
   

Filed: 834 DRIGGS AV Census Tract:   549 Health Area:  0500
ENTIRE Admin Area:   B - BROOKLYN Inspection Area:   B
BROOKLYN, NY 11211 Community Board:   301
Special Place Name:   HOTEL
DOB Cross Street(s):   ROEBLING STREET,    BROADWAY
Status:   K - CLOSED/CANCELLED 12/12/2013
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  10/26/2011 12:14 AM
Application Entered:   10/26/2011 Job Start Date:   10/26/2011
Last Change:   12/12/2013 Job End Date:   02/26/2012
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   BEST, J       On     12/10/2013      
Field Disp:   K - OK TO CANCEL
Energize Recommendation:  
Objection Disposition:  

License #: 010765 Licensee Name: CESAR QUERY
Firm: 002004 Firm Name: C.Q. ELECTR'L CONTRG CORP
Firm Phone: 718-204-9255  Firm Address: 723 EAST 135TH STREET BRONX NY 10454 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $1,975.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   H - Hotel
Special Cert Approval:  
Advisory Board Approval:   REQUIRED
Advisory Board Categories:      K - 1000 KVA SERVICE                            
Advisory Board Approval # / Submittal #:   50898
Owner / Occup: JUAN FIGUEROA
Owner Business Name: DOME VOYAGERS, LLC
Authorized Representative:  MIGUEL TRILLOS
Relationship To Owner:   CONSTRUCTION MANAGER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  3  200 AMP
C. 201 Up to 600 AMPS  6  400 AMP.
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  2  2000 AMP.
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  2  4/0
D. Over 250 MCM  5  600 MCM
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 1
Existing Meters 0 + New Meters 1 - Removed Meters 0 = Total Meters 1

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 10/26/2011 Notice:  
Power Issued: 10/26/2011 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  DOB-2K11-082 2000 AMP SERVICE ONLY

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B343842
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/10/2013 12/12/2013 JSB K (15) (0) Y
INSPECTION COMMENTS: N