BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B339904
Premises: 214 CLINTON STREET BROOKLYN BIN: 3002957     Block: 285   Lot: 30
   
Application Completed and Certified

Filed: 214 CLINTON ST Census Tract:   45 Health Area:  2300
1A Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11201 Community Board:   306
DOB Cross Street(s):   ATLANTIC AVENUE,    PACIFIC STREET
Status:   C - JOB IS SIGNED OFF 05/02/2012
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  06/21/2011 1:15 PM
Application Entered:   06/21/2011 Job Start Date:   06/21/2011
Last Change:   05/02/2012 Job End Date:   06/20/2012
Appointment Status:   
Last Inspection By:   JAMES CLANCY       On     03/08/2012      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011041 Licensee Name: SALVATORE CHIARAMONTE
Firm: 003893 Firm Name: L&B ELEC'L INTERNATIONAL
Firm Phone: 347-295-0380  Firm Address: 150-50 11TH AVENUE WHITESTONE NY 11357 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $61.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   A - One Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: ADVANCED MANAGEMENT
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001    15             
Buildings Total 15                
Total Units : 35 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 01/03/2012
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B339904
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/27/2011 01/03/2012 FMO A (60) (4) Y
INSPECTION COMMENTS: N
 
(2) 03/08/2012 03/13/2012 JMZ C R (45) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B339904
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 19) DEFECTIVE WIRING IS IN USE
DEFECTIVE BREAKER IN PANEL
RSLV 12/27/2011 12/27/2011 03/08/2012
 
002 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
NO AFCI PROVIDED IN SLEEPING AREA
RSLV 12/27/2011 12/27/2011 03/08/2012
 
003 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
KNOCKOUTS MISSING IN PANEL
RSLV 12/27/2011 12/27/2011 03/08/2012
 
004 ( 53) GFCI HAS NOT BEEN PROVIDED
NO GFCI PROVIDED ON KITCHEN COUNTER 210.8
RSLV 12/27/2011 12/27/2011 03/08/2012



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order