| NYC Department of Buildings | ||
| Electrical Application Details for App #: B339215 | ||
| Premises: 125 EASTERN PARKWAY BROOKLYN | BIN: 3029629 Block: 1179 Lot: 61 |
| Application Completed and Certified | ||
| Filed: | 125 EASTERN PARKWAY | Census Tract: 215 | Health Area: 2720 | |
| APT 6C | Admin Area: B - BROOKLYN | Inspection Area: D | ||
| BROOKLYN, NY 11238 | Community Board: 308 | |||
| Related Job Number: 320272361 | |||
| DOB Cross Street(s): UNDERHILL AVENUE, WASHINGTON AVENUE | |||
| Status: C - JOB IS SIGNED OFF 12/28/2011 | |||
| Request Type: A - APPLICATION | eFiled: YES | Permit Issued: 05/31/2011 10:55 AM | |
| Application Entered: 05/31/2011 | Job Start Date: 06/01/2011 | ||
| Last Change: 12/28/2011 | Job End Date: 12/12/2011 | ||
| Appointment Status: | |||
| Last Inspection By: DOYLEY, DEXTER On 12/23/2011 | |||
| Field Disp: C - INSPECTION PASSED | |||
| Energize Recommendation: E - ISSUE POWER AUTH | |||
| Objection Disposition: R - REMOVED | |||
| License #: | 011838 | Licensee Name: | VINCENZO NAPOLITANO | |
| Firm: | 003445 | Firm Name: | NAPSTAR ELECTRIC INC | |
| Firm Phone: | 718-384-2939 | Firm Address: | 647 METROPOLITAN AVE BROOKLYN NY 11211 | |
| Work Started or Filed by Others: NO | ||||||||
| Work Category: R - REHABILITATION | Work To Be Done:
1 - SERVICE WORK/NOTIFY UTILITY 6 - GENERAL WIRING |
Total Fee: $70.50 | ||||||
| Other Work: | ||||||||
| Work Related to a New or Amended Certificate of Occupancy: NO | ||||||||
| This Job Regulated by the NYC Energy Conservation Code: No | ||||||||
| Building Used As: L - Five Or More Family | |||||||
| Special Cert Approval: | |||||||
| Advisory Board Approval: NOT APPLICABLE | |||||||
| Owner / Occup: | BENITO POLANCO | ||||||
| Owner Business Name: | ARBERN 125 EASTERN PARKWA | ||||||
| Authorized Representative: VINCENZO NAPOLITANO | |||||||
| Relationship To Owner: LICENSED ELECTRICIAN | |||||||
|
|
| Floor | Apt. | Number Of Outlets | No. Of Fixtures |
Motors / Generators | Heaters | Transformers | ||||||
| Fixt | Receptacles | Switch | Num | Total HP KW | Num | Total KW | Num | Total KVA | ||||
| ATT | A/C | |||||||||||
| 006 | 6C | 12 | 34 | 2 | 12 | 12 | ||||||
| Buildings Total | 12 | 34 | 2 | 12 | 12 | |||||||
| Total Units : 72 units | ||||||||||||
| Signs: | Field Connect: | 0 | Field Inspect: | 0 | Tags: | ||
| Meter Request to Utility | #3-Wire | 2 | #4-Wire | 0 | #10-Wire | 0 | |
| Existing Meters | 2 | + New Meters | 0 | - Removed Meters | 1 | = Total Meters | 1 |
| Power Auth Flag: | I - ISSUED | Objection Flag: | |
| Power Requested: | 05/31/2011 | Notice: | 1 - FIRST NOTICE 10/18/2011 |
| Power Issued: | 05/31/2011 | Response: |
| Follow-Up: | K - (CLOSED) | ||
| Contractor's Comments: GENERAL WIRING APT 6C | |||
|
|