Electrical Application Details for App #: B337774
Premises: 145 VANDERBILT AVENUE BROOKLYN BIN: 3054246     Block: 1887   Lot: 4
   
Application Completed and Certified

Filed: 145 VANDERBILT AV Census Tract:   187 Health Area:  1200
1 FAMILY HOUSE Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11205 Community Board:   302
Special Place Name:   PARK AVE
DOB Cross Street(s):   PARK AVENUE,    MYRTLE AVENUE
Status:   C - JOB IS SIGNED OFF 05/10/2013
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  04/14/2011 10:14 AM
Application Entered:   04/14/2011 Job Start Date:   04/18/2011
Last Change:   05/10/2013 Job End Date:   07/08/2011
Appointment Status:   
Last Inspection By:   DOYLEY, DEXTER       On     03/26/2013      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010992 Licensee Name: GLENMORE HARVEY
Firm: 002334 Firm Name: WHYNN ELECTRIC CORP.
Firm Phone: 718-770-7288  Firm Address: 138-01 SPRINGFIELD BLVD QUEENS NY 11413 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $150.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   A - One Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: BLIGNA JOHNSON
Owner Business Name: PRIVATE HOUSE
Authorized Representative:  BELIGNA JONHSON
Relationship To Owner:   OWNER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  1X100AMPS
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  3  1SET
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  2  2X20-1 CIR.BRKR. PANEL
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001    35  30  20               
002    10  15                 
Buildings Total 45  45  28                  
Total Units : 120 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 1 + New Meters 0 - Removed Meters 0 = Total Meters 1

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 04/14/2011 Notice: 1 - FIRST NOTICE 03/21/2013
Power Issued: 04/14/2011 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  INSTALL 1X100AMPS MAIN BRK. PANEL WITH 6OAMP SUB. MAIN BRKR.FOR A 12 CIR, 20AMPS SINGLE POLE BRKRS.INSTALL TWO SMOKE DETECTOR/

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B337774
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/25/2013 03/12/2013 CJE G (5) (0) Y
INSPECTION COMMENTS: N
 
(2) 02/25/2013 03/12/2013 CJE A E (70) (2) Y
INSPECTION COMMENTS: N
 
(3) 01/29/2013 03/21/2013 CCH V R E (65) (9) Y
INSPECTION COMMENTS: CHECK BOLT IN MAIN BREAKER
 
(4) 03/26/2013 04/01/2013 DEX C R E (30) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B337774
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 5) SERVICE GROUNDING CONDUCTOR HAS NOT BEEN INSTALLED PROPERLY
WATER GROUND NOT CONTINOUS 250.24 (C)
RSLV 02/25/2013 02/25/2013 01/29/2013
 
002 (242) SERVICE ENTRANCE RACEWAY IS NOT SEALED
CIRCUITS NOT GROUPED ART 300.3 (B) IN ALL PANELS
RSLV 02/25/2013 02/25/2013 01/29/2013
 
003 ( 37) MOTOR DISCONNECT SWITCH HAS NOT BEEN PROVIDED
BOILER DIS SW NOT ON OUTSIDE ROOM
RSLV 01/29/2013 01/29/2013 03/26/2013
 
004 ( 53) GFCI HAS NOT BEEN PROVIDED
BOILER ROOM OUTLET NOT GFCI
RSLV 01/29/2013 01/29/2013 03/26/2013
 
005 (999) OTHER
A KITCHEN ISLAND NO OUTLET INSTALLED 210.52 C.2
RSLV 01/29/2013 01/29/2013 03/26/2013
 
006 ( 16) DEFECTIVE LIGHTING FIXTURES ARE IN USE
CLOSET LIGHT NO GLOBE
RSLV 01/29/2013 01/29/2013 03/26/2013
 
007 (999) OTHER
B BOILER ROOM LIGHT NO DANGER PROOF COVER 410.4
RSLV 01/29/2013 01/29/2013 03/26/2013
 
008 (999) OTHER
C REAR LIGHT NOT SUITABLE FOR WET LOCATION 410.4
RSLV 01/29/2013 01/29/2013 03/26/2013
 
009 ( 42) BUSHINGS ARE MISSING OR LOOSE
NO RED BUSHING ON BOX CABLE IN PANEL
RSLV 01/29/2013 01/29/2013 03/26/2013
 
010 (999) OTHER
D NO ARC FAULT FOR ALL BEDROOMS 210.12
RSLV 01/29/2013 01/29/2013 03/26/2013
 
011 ( 35) APPROVED OUTLETS HAVE NOT BEEN PROVIDED FOR AIR CONDITIONERS
NO AC OUTLET NOT IN ALL ROOMS
RSLV 01/29/2013 01/29/2013 03/26/2013