BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B327482
Premises: 309 EAST 19 STREET BROOKLYN BIN: 3118811     Block: 5162   Lot: 68
   
Application Completed and Certified

Filed: 309 E 19 ST Census Tract:   514 Health Area:  7210
ELEVATOR SHAFT AND MACHINE ROO Admin Area:   B - BROOKLYN Inspection Area:   K
BROOKLYN, NY 11226 Community Board:   314
DOB Cross Street(s):   CORTELYOU ROAD,    DORCHESTER ROAD
Status:   C - JOB IS SIGNED OFF 04/18/2012
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  05/24/2010 10:35 AM
Application Entered:   05/24/2010 Job Start Date:   06/01/2010
Last Change:   04/18/2012 Job End Date:   09/09/2010
Appointment Status:   
Last Inspection By:   THOMAS, PATRICIA       On     04/09/2012      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010693 Licensee Name: STEVEN M DUFFY
Firm: 003508 Firm Name: ERIN ELEC'L CONTR'G INCOR
Firm Phone: 718-720-3200  Firm Address: 17 RECTOR STREET STATEN ISLAND NY 10310 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
3 - ELEVATOR/ESCALATOR/MATERIAL LIFT
Total Fee:  $173.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: PANKAJ PRASAD
Owner Business Name: PRASAD MANAGEMENT LLC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  8
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  1  125
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
EPT                 
PEN                 
Buildings Total                 
Total Units : 8 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 04/11/2011 Notice: C - CALL TO OFFICE 02/09/2012
Power Issued: 04/11/2011 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B327482
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/24/2010 11/29/2010 DEX N (35) (0) Y
INSPECTION COMMENTS: N
 
(2) 02/02/2011 02/07/2011 JMZ P (15) (0) Y
INSPECTION COMMENTS: CONTRACTOR NO SHOW, EQUIPMENT NOT ACCESSIBLE
 
(3) 04/05/2011 04/11/2011 MC2 V E (55) (5) Y
INSPECTION COMMENTS: NOT A FINAL INSPECTION
 
(4) 07/18/2011 07/25/2011 JMZ A R (75) (5) Y
INSPECTION COMMENTS: N
 
(5) 02/01/2012 02/09/2012 PAT H X (45) (0) Y
INSPECTION COMMENTS: N
 
(6) 04/09/2012 04/18/2012 PAT C R (30) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B327482
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
ELEV DIS SWITCH MIN WORKING SPACE NOT PROVIDED 110.26
RSLV 04/05/2011 04/05/2011 07/18/2011
 
002 (999) OTHER
ELEV CAB LIGHT DIS PANEL MOUNTED UPSIDE DOWN C.B DOWN IN ON POSITIONNOT PROVIDED
RSLV 04/05/2011 04/05/2011 07/18/2011
 
003 (999) OTHER
ELEV LIGHT DIS NEUTRAL NOT PROVIDED IN PANEL
RSLV 04/05/2011 04/05/2011 07/18/2011
 
004 (999) OTHER
ELEV CONTROL PANEL GROUNDING CONDUCTORS TRIPLE LUGGED 110.14ATERMINAL STRIP NECESSARY
RSLV 04/05/2011 04/05/2011 07/18/2011
 
005 (999) OTHER
ELEV BRAKE CONTROL WIRING ARMORED CABLE TAPED FITTING NOT MAKINGCONTINOUS GROUND OF RACEWAY 300
RSLV 04/05/2011 04/05/2011 07/18/2011
 
006 ( 42) BUSHINGS ARE MISSING OR LOOSE
BUSHING MISSING AT DISCONNECT SWITCH
RSLV 07/18/2011 02/01/2012 04/09/2012
 
007 ( 29) OUTLET BOXES ARE NOT COVERED
BUSHING MISSING AT SPLICE BOX
RSLV 07/18/2011 02/01/2012 04/09/2012
 
008 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
DISCONNECT SWITCH ATTACHED AT GROUND TO ENCLOSURE
RSLV 07/18/2011 02/01/2012 04/09/2012
 
009 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
MULTI-CONDUCTOR IN BUG NUT GROUNDS IN CONTROLLER
RSLV 07/18/2011 02/01/2012 04/09/2012
 
010 ( 25) ARMORED CABLES ARE NOT PROPERLY TERMINATED
BRAKE WIRE CONNECTOR NOT TERMINATED
RSLV 07/18/2011 02/01/2012 04/09/2012



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back