BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B323660
Premises: 1543 WEST 1 STREET BROOKLYN BIN: 3174676     Block: 6606   Lot: 26
   
Application Completed and Certified

Filed: 1543 W 1ST ST Census Tract:   434 Health Area:  8521
ELECTRICAL ROOM AND BASEMENT Admin Area:   B - BROOKLYN Inspection Area:   N
BROOKLYN, NY 11204 Community Board:   311
DOB Cross Street(s):    65 STREET,    AVENUE P
Status:   C - JOB IS SIGNED OFF 04/20/2010
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  01/14/2010 9:44 AM
Application Entered:   01/14/2010 Job Start Date:   01/14/2010
Last Change:   04/20/2010 Job End Date:   06/30/2010
Appointment Status:   
Last Inspection By:   MOSES, FITZROY       On     04/13/2010      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 010502 Licensee Name: RAYMOND T JOHNSON
Firm: 003361 Firm Name: ELMAC ELECTRIC INC.
Firm Phone: 718-894-9727  Firm Address: 61-20 COOPER AVENUE GLENDALE NY 11385 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $108.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   CELL SITE
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: CLEARWIRE TECHNOLOGIES
Authorized Representative:  OSCAR CARILLO
Relationship To Owner:   PROJECT MANAGER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  1 PH. 100A
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  3 # 3
B. Over #2 to 1/0  1  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  20 CIRCUITS
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 6 + New Meters 1 - Removed Meters 0 = Total Meters 7

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 01/14/2010 Notice:  
Power Issued: 01/14/2010 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  INSTALL 100A SERVICE AND RISER FOR CLEARWIRE

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B323660
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 04/13/2010 04/20/2010 FMO C E (60) (0) Y
INSPECTION COMMENTS: N




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order