Electrical Application Details for App #: B315216
Premises: 443 LINCOLN PLACE BROOKLYN BIN: 3029562     Block: 1177   Lot: 40
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 443 LINCOLN PL Census Tract:   215 Health Area:  2720
NONE Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11238 Community Board:   308
DOB Cross Street(s):   WASHINGTON AVENUE,    CLASSON AVENUE
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   04/08/2009 Job Start Date:   04/05/2009
Last Change:   08/22/2025 Job End Date:   06/09/2009
Appointment Status:   
Last Inspection By:   PETER GREENE       On     11/23/2010      
Field Disp:   N - NO ACCESS
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  Y - PARTLY REMOVED

License #: 011169 Licensee Name: LAWRENCE WALSH
Firm: 002541 Firm Name: BDS ELECTRIC CORP.
Firm Phone: 718-598-0000  Firm Address: 220-04 HEMPSTEAD AVENUE QUEENS VILLAGE NY 11429 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $297.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: TETRA GROUP, LLC
Authorized Representative:  MANASHE GROSSMAN
Relationship To Owner:   OWNER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  6  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  6  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001                       
002                       
003                       
Buildings Total   18                      
Total Units : 18 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 6 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: V - OBJECTION(S) EXIST
Power Requested: 04/08/2009 Notice: 1 - FIRST NOTICE 06/02/2010
Power Issued: 04/08/2009 Response:  

Follow-Up:
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B315216
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/18/2009 11/20/2009 PGR N (20) (0) Y
INSPECTION COMMENTS: N
 
(2) 01/06/2010 01/07/2010 PGR V E (50) (9) Y
INSPECTION COMMENTS: ONLY ACCESS TO ONE APT
 
(3) 03/29/2010 04/02/2010 FMO H X (40) (0) Y
INSPECTION COMMENTS: NA TO APTS
 
(4) 05/17/2010 06/02/2010 JMZ A Y E (45) (5) Y
INSPECTION COMMENTS: N
 
(5) 11/23/2010 11/29/2010 PGR N (55) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B315216
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 5) SERVICE GROUNDING CONDUCTOR HAS NOT BEEN INSTALLED PROPERLY
BSMT SER/GRN RACEWAY
RSLV 01/06/2010 03/29/2010 05/17/2010
 
002 ( 42) BUSHINGS ARE MISSING OR LOOSE
BSMT PLP PANEL MISSING BUSHING
RSLV 01/06/2010 03/29/2010 05/17/2010
 
003 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
BSMT METER BANK KO SEAL
RSLV 01/06/2010 03/29/2010 05/17/2010
 
004 ( 1) SERVICE EQUIPMENT ENCLOSURES ARE NOT BONDED TOGETHER
BSMT SER/SW
RSLV 01/06/2010 03/29/2010 05/17/2010
 
005 ( 7) EMT IS NOT PROPERLY SUPPORTED (TYPE:EMT)
BSMT 11/4 RACEWAY
RSLV 01/06/2010 03/29/2010 05/17/2010
 
006 ( 29) OUTLET BOXES ARE NOT COVERED
BSMT THROUGHOUT
RSLV 01/06/2010 03/29/2010 05/17/2010
 
007 ( 30) OUTLET BOXES ARE NOT SECURED
BSMT 10X10 PULL BOX
RSLV 01/06/2010 03/29/2010 05/17/2010
 
008 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
BSMT NEUTRAL NOT PROVIDED IN BSMT RACEWAY FOR APT
RSLV 01/06/2010 03/29/2010 05/17/2010
 
009 (999) OTHER
ALL/FL OUTLET 250.146
OPEN 01/06/2010 05/17/2010
 
010 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
PLP GROUND TRANSFORMER
OPEN 05/17/2010 05/17/2010
 
011 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
PLP KO'S MISSING
OPEN 05/17/2010 05/17/2010
 
012 ( 5) SERVICE GROUNDING CONDUCTOR HAS NOT BEEN INSTALLED PROPERLY
DRIVEN GROUND DOUBLE LUG
OPEN 05/17/2010 05/17/2010
 
013 ( 53) GFCI HAS NOT BEEN PROVIDED
GFI BELOW PLP
OPEN 05/17/2010 05/17/2010
 
014 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
BATHROOM RECEPTACLES ON KITCHEN COUNTER CICUIT APT.2R
OPEN 05/17/2010 05/17/2010