Electrical Application Details for App #: B314965
Premises: 822 42 STREET BROOKLYN BIN: 3018340     Block: 925   Lot: 14
   
Application Completed and Certified

Filed: 822 42 ST Census Tract:   92 Health Area:  6600
BASEMENT, 1FL, 2 FL Admin Area:   B - BROOKLYN Inspection Area:   J
BROOKLYN, NY 11232 Community Board:   312
Related Job Number:    310299502
DOB Cross Street(s):    8 AVENUE,    9 AVENUE
Status:   C - JOB IS SIGNED OFF 09/28/2009
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  04/01/2009 2:35 PM
Application Entered:   04/01/2009 Job Start Date:   04/03/2009
Last Change:   09/28/2009 Job End Date:   05/29/2009
Appointment Status:   
Last Inspection By:   O'HARE, R.J.       On     09/23/2009      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011983 Licensee Name: PETER Z LI
Firm: 003654 Firm Name: P.L. ELEC'L CONTR'G CORP
Firm Phone: 212-608-8868  Firm Address: 25 MONROE STREET.1ST FLOOR NEW YORK NY 10002 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $65.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: QIU MEI LIN
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS    12             
001    15             
002    15             
Buildings Total 21  42  20  21                
Total Units : 113 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 05/18/2009
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B314965
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/11/2009 05/18/2009 RJO A (25) (6) Y
INSPECTION COMMENTS: N
 
(2) 09/23/2009 09/28/2009 RJO C R (40) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B314965
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 19) DEFECTIVE WIRING IS IN USE
RANGE HOOD OPEN WIRE B, 1 AND 2 FLRS
RSLV 05/11/2009 05/11/2009 09/23/2009
 
002 ( 19) DEFECTIVE WIRING IS IN USE
BATHROOM GFI ABOVE SINK AT 1ST AND 2ND FLRS
RSLV 05/11/2009 05/11/2009 09/23/2009
 
003 ( 53) GFCI HAS NOT BEEN PROVIDED
OUTSIDE FRONT
RSLV 05/11/2009 05/11/2009 09/23/2009
 
004 ( 53) GFCI HAS NOT BEEN PROVIDED
BASEMENT BY STOVE
RSLV 05/11/2009 05/11/2009 09/23/2009
 
005 ( 63) RECEPTACLE OUTLETS NOT IN SUFFICIENT NUMBER
KITCHEN COUNTER TOP NO TWO CIRCUITS AND FIXTURES ON WITH COUNTER TOPAT BASEMENT 1ST AND 2ND FLRS
RSLV 05/11/2009 05/11/2009 09/23/2009
 
006 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
NO ARCH FAULT FOR LIGHTS , OUTLETS, A/C AT ALL BEDROOMS BASEMENT -2ND FLRS
RSLV 05/11/2009 05/11/2009 09/23/2009