BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B314728
Premises: 324 SACKETT STREET BROOKLYN BIN: 3323342     Block: 428   Lot: 14
   
Application Completed and Certified

Filed: 324 SACKETT ST Census Tract:   75 Health Area:  2500
1ST 2ND, 3RD FLOOR Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11231 Community Board:   306
Special Place Name:   BROOKLYN
Related Job Number:    310233832
DOB Cross Street(s):   COURT STREET,    SMITH STREET
Status:   C - JOB IS SIGNED OFF 12/17/2009
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  03/25/2009 11:56 AM
Application Entered:   03/25/2009 Job Start Date:   03/25/2009
Last Change:   12/17/2009 Job End Date:   07/15/2009
Appointment Status:   
Last Inspection By:   PETER GREENE       On     09/29/2009      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 011288 Licensee Name: DENNIS KARAGOUNIS
Firm: 002217 Firm Name: YORK ELEC'L CONTR'S INC.
Firm Phone: 718-353-7227  Firm Address: 162-10 CROCHERON AVENUE FLUSHING NY 11358 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $198.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JOSH TAYLOR
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  200-AMP SW
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  2  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  2  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
002    30  27    19               
003    10  12                 
Buildings Total 40  39    26                  
Total Units : 105 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 6 + New Meters 1 - Removed Meters 4 = Total Meters 3

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 03/25/2009 Notice:  08/28/2009
Power Issued: 03/25/2009 Response: V - OBJ WAS REMOVED 09/24/2009

Follow-Up: K - (CLOSED)
Contractor's Comments:  CONVERTION FROM EXISTING 4 FAMILY TO 2-FAMILY NEW WIRING THROUGHOUT THE BUILDING. EXISTING RISER

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B314728
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 08/26/2009 08/28/2009 HMC V E (30) (2) Y
INSPECTION COMMENTS: N
 
(2) 09/29/2009 10/02/2009 PGR C R E (5) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B314728
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 5) SERVICE GROUNDING CONDUCTOR HAS NOT BEEN INSTALLED PROPERLY
GROUND FL GROUND CONDUCTOR TO ELECTRODE UNDERSIZE
RSLV 08/26/2009 08/26/2009 09/29/2009
 
002 (999) OTHER
2ND 3RD FL THROUGHOUT ALL OUTLETS GFI OUTLETS 250.146
RSLV 08/26/2009 08/26/2009 09/29/2009