BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B313273
Premises: 32 HOYT STREET BROOKLYN BIN: 3000489     Block: 164   Lot: 36
   

DOB NOW: Inspections


Filed: 40 HOYT ST. Census Tract:   37 Health Area:  2400
ENTIRE Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11201 Community Board:   302
DOB Cross Street(s):   LIVINGSTON STREET,    SCHERMERHORN STREET
Status:   K - CLOSED/CANCELLED 02/20/2024
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  02/05/2009 6:54 PM
Application Entered:   02/05/2009 Job Start Date:   02/05/2009
Last Change:   02/20/2024 Job End Date:   12/02/2009
Appointment Status:   
Last Inspection By:   MARCIN DUBAJ       On     02/20/2024      
Field Disp:   K - OK TO CANCEL
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 009252 Licensee Name: MORRIS HELLER
Firm: 000647 Firm Name: HELLER ELECTRIC CO., INC.
Firm Phone: 718-871-0800  Firm Address: 620 CONEY ISLAND AVE BROOKLYN NY 11218 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $630.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Commercial/Residential (3  Stores, 4 Apartments)
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JACOB MARCIANO
Owner Business Name: LEOR REALTY
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  6  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  6  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  2  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  4  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
002             
003             
004             
005             
Buildings Total 12  20  12                
Total Units : 60 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 5 #4-Wire 4 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 02/05/2009 Notice: 1 - FIRST NOTICE 02/08/2016
Power Issued: 02/05/2009 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B313273
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/05/2016 02/08/2016 HRB V (84) (11)
INSPECTION COMMENTS: FAILED
 
(2) 07/12/2017 07/12/2017 SVJ K Y (1) (0)
INSPECTION COMMENTS: SEE APP B430259
 
(3) 02/20/2024 02/20/2024 MJD K R (5) (0)
INSPECTION COMMENTS: DATA MIGRATION, IN HOUSE, INSPECTION DONE BY SVJ ON 07/12/20217, OBJECTIONS REMOVED

OBJECTION FOR APPLICATION #: B313273
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 15) FLEXIBLE CORDS USED AS PERMANENT WIRING METHOD
(ALL FLOORS) THROUGH OUT ALL FLOORS
RSLV 02/05/2016 02/05/2016 07/12/2017
 
002 ( 15) FLEXIBLE CORDS USED AS PERMANENT WIRING METHOD
(ALL FLOORS) 2ND AND 3RD FLOOR APTS
RSLV 02/05/2016 02/05/2016 07/12/2017
 
003 ( 16) DEFECTIVE LIGHTING FIXTURES ARE IN USE
(ALL FLOORS) 2ND, 3RD AND BASEMENT
RSLV 02/05/2016 02/05/2016 07/12/2017
 
004 ( 16) DEFECTIVE LIGHTING FIXTURES ARE IN USE
(ALL FLOORS) THROUGH OUT
RSLV 02/05/2016 02/05/2016 07/12/2017
 
005 ( 19) DEFECTIVE WIRING IS IN USE
(ALL FLOORS) THROUGH OUT ALL FLOORS AND BASEMENT
RSLV 02/05/2016 02/05/2016 07/12/2017
 
006 ( 24) ARMORED CABLES ARE NOT PROPERLY SECURED
(ALL FLOORS) BASEMENT 2ND AND 3RD FLOOR
RSLV 02/05/2016 02/05/2016 07/12/2017
 
007 ( 25) ARMORED CABLES ARE NOT PROPERLY TERMINATED
(ALL FLOORS) BASEMENT 2ND AND 3RD FLOOR
RSLV 02/05/2016 02/05/2016 07/12/2017
 
008 ( 29) OUTLET BOXES ARE NOT COVERED
(ALL FLOORS) THROUGH OUT
RSLV 02/05/2016 02/05/2016 02/20/2024
 
009 ( 33) KNOCKOUTS ARE NOT CLOSED IN OUTLET BOX
(ALL FLOORS) THROUGH OUT
RSLV 02/05/2016 02/05/2016 02/20/2024
 
010 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
(ALL FLOORS) ALL PANELS AND BASEMENT SERVICE SWITCHES
RSLV 02/05/2016 02/05/2016 07/12/2017
 
011 ( 45) FIXTURE NOT INSTALLED IN AN APPROVED MANNER
(ALL FLOORS) THROUGH OUT BUILDING
RSLV 02/05/2016 02/05/2016 07/12/2017



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back