BIS Menu  |  Applications  |  Plumb. Inspections  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B310211
Premises: 285 LIVINGSTON STREET BROOKLYN BIN: 3000482     Block: 161   Lot: 64
   
Application Completed and Certified

Filed: 285 LIVINGSTON ST Census Tract:   37 Health Area:  2400
ALL FLOORS Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11217 Community Board:   302
DOB Cross Street(s):   HANOVER PLACE,    NEVINS STREET
Status:   C - JOB IS SIGNED OFF 06/07/2010
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  10/27/2008 11:06 PM
Application Entered:   10/27/2008 Job Start Date:   10/29/2008
Last Change:   06/07/2010 Job End Date:   10/30/2009
Appointment Status:   
Last Inspection By:   PETER GREENE       On     04/28/2010      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 011403 Licensee Name: GEORGIOS KOUSPOS
Firm: 002841 Firm Name: CY ELECTRICAL CORP.
Firm Phone: 718-545-8557  Firm Address: 30-16 31ST STREET,1ST FLOOR ASTORIA NY 11102 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $750.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   O - Office Bldg
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MATTHEW MIRONES
Owner Business Name: ARTMAST REALTY INC
Authorized Representative:  MATTHEW MIRONES
Relationship To Owner:    PARTNER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  3  100 AMP 3-PH
B. 101 Up to 200 AMPS  2  200 AMP 3-PH
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  5  3/0 THHN
D. Over 250 MCM  2  2 SETS OF 500MCM
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  5  3-PHASE 40CRT 4-WIRE
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS                       
GND                       
001                 
002                 
003                 
Buildings Total                 
Total Units : 14 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 4 #10-Wire 0
Existing Meters 4 + New Meters 4 - Removed Meters 4 = Total Meters 4

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 10/27/2008 Notice:  
Power Issued: 10/27/2008 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  NEW SERVICE UPGRADE ALONG WITH NEW POWER RISERS AND PANEL ON EACH FLOOR

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B310211
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 04/28/2010 04/30/2010 PGR C (55) (0) Y
INSPECTION COMMENTS: N




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Applications  |  Plumb. Inspections  |  Electrical Inspection Work Order  |  Back