![]() |
|
|
| NYC Department of Buildings | ||
| Electrical Application Details for App #: B304332 | ||
| Premises: 32 LUQUER STREET BROOKLYN | BIN: 3008329 Block: 520 Lot: 19 |
| Application Completed and Certified | ||
| Filed: | 32 LUQUER ST | Census Tract: 59 | Health Area: 4100 | |
| ENTIRE BLDG | Admin Area: B - BROOKLYN | Inspection Area: C | ||
| BROOKLYN, NY 11231 | Community Board: 306 | |||
| DOB Cross Street(s): COLUMBIA STREET, HICKS STREET | |||
| Status: C - JOB IS SIGNED OFF 06/23/2008 | |||
| Request Type: A - APPLICATION | eFiled: NO | ||
| Application Entered: 05/16/2008 | Job Start Date: 05/20/2008 | ||
| Last Change: 06/23/2008 | Job End Date: 12/30/2008 | ||
| Appointment Status: | |||
| Last Inspection By: HUGH MCKESSEY On 06/21/2008 | |||
| Field Disp: C - INSPECTION PASSED | |||
| Energize Recommendation: | |||
| Objection Disposition: | |||
| License #: | 010715 | Licensee Name: | TIMOTHY M MCDONALD | |
| Firm: | 001937 | Firm Name: | MAC ELECT'L CONTR. INC. | |
| Firm Phone: | 718-758-3500 | Firm Address: | 2807 FLATBUSH AVENUE BROOKLYN NY 11234 | |
| Work Started or Filed by Others: NO | ||||||||
| Work Category: R - REHABILITATION | Work To Be Done:
1 - SERVICE WORK/NOTIFY UTILITY 6 - GENERAL WIRING 8 - BOILER/BURNER WIRING |
Total Fee: $360.50 | ||||||
| Other Work: | ||||||||
| Work Related to a New or Amended Certificate of Occupancy: YES | ||||||||
| This Job Regulated by the NYC Energy Conservation Code: | ||||||||
| Building Used As: E - Four Family | |||||||
| Special Cert Approval: | |||||||
| Advisory Board Approval: NOT APPLICABLE | |||||||
| Owner / Occup: | GINO VITALE | ||||||
| Authorized Representative: | |||||||
| Relationship To Owner: | |||||||
|
|
| Floor | Apt. | Number Of Outlets | No. Of Fixtures |
Motors / Generators | Heaters | Transformers | ||||||
| Fixt | Receptacles | Switch | Num | Total HP KW | Num | Total KW | Num | Total KVA | ||||
| ATT | A/C | |||||||||||
| Buildings Total | 80 | 140 | 12 | 80 | 160 | |||||||
| Total Units : 472 units | ||||||||||||
| Signs: | Field Connect: | 0 | Field Inspect: | 0 | Tags: | ||
| Meter Request to Utility | #3-Wire | 5 | #4-Wire | 0 | #10-Wire | 0 | |
| Existing Meters | 0 | + New Meters | 0 | - Removed Meters | 0 | = Total Meters | 0 |
| Power Auth Flag: | I - ISSUED | Objection Flag: | |
| Power Requested: | 05/16/2008 | Notice: | |
| Power Issued: | 05/16/2008 | Response: |
| Follow-Up: | K - (CLOSED) | ||
| Contractor's Comments: | |||
|
|
| INSP ID |
FIELD DATE |
DISP DATE |
INSP ID |
FLD DISP |
OBJ DISP |
ENRG REC |
TIME INSP |
REINSP DATE |
NEW OBJ |
APPT FLAG |
| (1) | 06/21/2008 | 06/23/2008 | HMC | C | (30) | (0) | Y | |||
| INSPECTION COMMENTS: | N | |||||||||