NYC Department of Buildings
Electrical Application Details for App #: B300214
Premises: 30 MONTGOMERY PLACE BROOKLYN BIN: 3024999     Block: 1073   Lot: 19
   
Application Completed and Certified

Filed: 30 MONTGOMERY PL Census Tract:   165 Health Area:  4500
1ST FLOOR AND BASEMENT Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11215 Community Board:   306
DOB Cross Street(s):    8 AVENUE,    PROSPECT PARK WEST
Status:   C - JOB IS SIGNED OFF 11/03/2008
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  01/24/2008 10:54 PM
Application Entered:   01/24/2008 Job Start Date:   01/28/2008
Last Change:   11/03/2008 Job End Date:   02/20/2008
Appointment Status:   
Last Inspection By:   MOSES, FITZROY       On     10/28/2008      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010922 Licensee Name: LARRY STEWART
Firm: 002396 Firm Name: KELLEN ELECTRIC CORP.
Firm Phone: 718-725-7403  Firm Address: 43-01 21ST STREET LONG ISLAND CITY NY 11101 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $199.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MARGARET HOLTAN
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  70 AMP DISCONNECTS
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  2  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  UP TO 20-1
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 36  10  18                
Total Units : 74 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 6 + New Meters 6 - Removed Meters 6 = Total Meters 6

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 01/24/2008 Notice: 1 - FIRST NOTICE 09/22/2008
Power Issued: 01/24/2008 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  UPGRADE EXISTING SERVICE AND REWIRE 1ST FLOOR APTALSO AD PLP FOR HOUSE LIGHTING

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B300214
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/18/2008 09/22/2008 PGR V E (20) (6)
INSPECTION COMMENTS: N
 
(2) 10/06/2008 10/14/2008 FMO J Y (40) (0)
INSPECTION COMMENTS: N
 
(3) 10/28/2008 11/03/2008 FMO C R E (5) (0)
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B300214
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 63) RECEPTACLE OUTLETS NOT IN SUFFICIENT NUMBER
1ST FLOOR KITCHEN COUNTER TOP
RSLV 09/18/2008 09/18/2008 10/06/2008
 
002 ( 1) SERVICE EQUIPMENT ENCLOSURES ARE NOT BONDED TOGETHER
BSMT SERV SW
RSLV 09/18/2008 10/06/2008 10/28/2008
 
003 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
BSMT SERV GRN RACEWAY ROD
RSLV 09/18/2008 10/06/2008 10/28/2008
 
004 ( 24) ARMORED CABLES ARE NOT PROPERLY SECURED
BSMT THROUGHOUT
RSLV 09/18/2008 10/06/2008 10/28/2008
 
005 (999) OTHER
BSMT MORE THAN SIX SER/SW PROVIDED 230.71
RSLV 09/18/2008 10/06/2008 10/28/2008
 
006 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
2ND FL BEDROOM A/C
RSLV 09/18/2008 10/06/2008 10/28/2008