Electrical Application Details for App #: B298805
Premises: 204 NORTH 11 STREET BROOKLYN BIN: 3061628     Block: 2299   Lot: 9
   
Application Completed and Certified

Filed: 214 N 11 ST Census Tract:   519 Health Area:  0700
ENTIRE BUILDING Admin Area:   B - BROOKLYN Inspection Area:   A
BROOKLYN, NY 11211 Community Board:   301
Related Job Number:    302044767
DOB Cross Street(s):   DRIGGS AVENUE,    ROEBLING STREET
Status:   C - JOB IS SIGNED OFF 03/17/2009
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  12/12/2007 10:02 AM
Application Entered:   12/12/2007 Job Start Date:   12/15/2007
Last Change:   03/17/2009 Job End Date:   12/01/2008
Appointment Status:   
Last Inspection By:   HUGH MCKESSEY       On     12/30/2008      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 011212 Licensee Name: PAUL LEFKOWITZ
Firm: 001756 Firm Name: BLZ ELECTRIC INC.
Firm Phone: 718-677-5900  Firm Address: 1243 EAST 15TH STREET BROOKLYN NY 11230 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
7 - HVAC WIRING
Total Fee:  $5,040.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   REQUIRED
Advisory Board Categories:      K - 1000 KVA SERVICE                            
Advisory Board Approval #:        Submittal #:   
Owner / Occup: ISSAC SCHWARTZ
Owner Business Name: YBG CONST.
Authorized Representative:  YAAKOV PFEIFFER
Relationship To Owner:   CONT.


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  5  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  120  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  5  
D. Over 250 MCM  15  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  120  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  6  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 1200  2000  300  1200  1200     50           
Total Units : 5950 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 12 #4-Wire 0 #10-Wire 1
Existing Meters 121 + New Meters 12 - Removed Meters 121 = Total Meters 12

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 12/12/2007 Notice: 1 - FIRST NOTICE 11/12/2008
Power Issued: 12/12/2007 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B298805
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/10/2008 11/12/2008 PGR V E (120) (12) Y
INSPECTION COMMENTS: CHECK FEEDER FROM SER/SW TO CONTROLLER #48466
 
(2) 12/30/2008 01/02/2009 HMC C R E (25) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B298805
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 5) SERVICE GROUNDING CONDUCTOR HAS NOT BEEN INSTALLED PROPERLY
BSMT SER/GRN RACEWAY AT WATER MAIN
RSLV 11/10/2008 11/10/2008 12/30/2008
 
002 ( 5) SERVICE GROUNDING CONDUCTOR HAS NOT BEEN INSTALLED PROPERLY
BSMT SER/GRN IN SER/SW NOT ON LINE SIDE
RSLV 11/10/2008 11/10/2008 12/30/2008
 
003 ( 21) CONDUCTORS HAVE NOT BEEN PROPERLY DE-RATED
BSMT ALL FEEDER IN 3IN RACEWAY FOR APT
RSLV 11/10/2008 11/10/2008 12/30/2008
 
004 ( 6) FEEDER DIAGRAM DID NOT ACCOMPANY APPLICATION FOR INSPECTION
ALL NEED LOAD CALCULATION FOR ENTIRE BUILDING
RSLV 11/10/2008 11/10/2008 12/30/2008
 
005 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
ROOF PANEL NEUTRAL BONDED
RSLV 11/10/2008 11/10/2008 12/30/2008
 
006 ( 29) OUTLET BOXES ARE NOT COVERED
ROOF PANEL MISS TRIM
RSLV 11/10/2008 11/10/2008 12/30/2008
 
007 ( 33) KNOCKOUTS ARE NOT CLOSED IN OUTLET BOX
BSMT DIST/B
RSLV 11/10/2008 11/10/2008 12/30/2008
 
008 ( 42) BUSHINGS ARE MISSING OR LOOSE
BSMT DIST/B
RSLV 11/10/2008 11/10/2008 12/30/2008
 
009 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
BSMT FIRE PUMP CONTROLLER REMOVED NEUTRAL
RSLV 11/10/2008 11/10/2008 12/30/2008
 
010 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
ALL WIRE TO DRYER OUTLET 10/2 USED
RSLV 11/10/2008 11/10/2008 12/30/2008
 
011 (999) OTHER
BSMT DOOR NOT AS PER DRAWING SER/ROOM
RSLV 11/10/2008 11/10/2008 12/30/2008
 
012 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
BSMT NEUTRAL BAR USED IN SPLICE BOX IN BSMT FOR APT
RSLV 11/10/2008 11/10/2008 12/30/2008