Premises: 301 HOOPER STREET BROOKLYN BIN: 3063605     Block: 2463   Lot: 21
   
Application Completed and Certified

Filed: 301 HOOPER ST Census Tract:   527 Health Area:  0600
FIRST FLOOR Admin Area:   B - BROOKLYN Inspection Area:   B
BROOKLYN, NY 11211 Community Board:   301
DOB Cross Street(s):   BROADWAY,    SOUTH 5 STREET
Status:   C - JOB IS SIGNED OFF 07/25/2011
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  09/21/2007 5:10 PM
Application Entered:   09/21/2007 Job Start Date:   09/21/2007
Last Change:   07/25/2011 Job End Date:   10/02/2007
Appointment Status:   
Last Inspection By:   DOYLEY, DEXTER       On     07/20/2011      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 009676 Licensee Name: CARL I WEISS
Firm: 002693 Firm Name: CITYWIDE ELEC'L CONTR'G C
Firm Phone: 718-805-2272  Firm Address: 14-06 AUGUSTINA AVE FAR ROCKAWAY NY 11691 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $108.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: B KAHAN
Owner Business Name: 301 HOOPER REALTY, LLC
Authorized Representative:  B KAHAN
Relationship To Owner:   PRESIDENT


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  2  4-3, TWO SETS
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  2  8/16 SINGLE PHASE
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 10  10                
Total Units : 45 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: C - CALL TO OFFICE 04/05/2011
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  AIRING AND DEVICES FOR TWO RESIDENTIAL APARTMENTS

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B295850
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/05/2010 01/11/2010 DEX N (35) (0) Y
INSPECTION COMMENTS: N
 
(2) 04/01/2010 04/08/2010 PAT V (60) (3) Y
INSPECTION COMMENTS: NO ACCESS TO THE BASEMENT
 
(3) 09/16/2010 09/20/2010 DEX N (30) (0) Y
INSPECTION COMMENTS: N
 
(4) 09/16/2010 09/20/2010 DEX N (30) (0) Y
INSPECTION COMMENTS: N
 
(5) 02/22/2011 02/28/2011 PAT A R (30) (4) Y
INSPECTION COMMENTS: N
 
(6) 03/30/2011 04/05/2011 FMO H X (5) (0) Y
INSPECTION COMMENTS: N
 
(7) 07/20/2011 07/25/2011 DEX C R (30) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B295850
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 63) RECEPTACLE OUTLETS NOT IN SUFFICIENT NUMBER
APARTMENT RECEPTACLES
RSLV 04/01/2010 04/01/2010 02/22/2011
 
002 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
APARTMENT BATHROOM SHOWER LIGHT
RSLV 04/01/2010 04/01/2010 02/22/2011
 
003 (999) OTHER
KITCHEN NO TWO SMALL APPLIANCE BRANCH CIRCUIT 210.52(B)(3)
RSLV 04/01/2010 04/01/2010 02/22/2011
 
004 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
APARTMENTS 1 AND 2.- ENTIRE LIVING ROOM SPACE NOT ON AFCI
RSLV 02/22/2011 03/30/2011 07/20/2011
 
005 ( 63) RECEPTACLE OUTLETS NOT IN SUFFICIENT NUMBER
APARTMENT 1 RECEPTACLE
RSLV 02/22/2011 03/30/2011 07/20/2011
 
006 (999) OTHER
APARTMENT #1- SHOWER LIGHT NOT APPROVED 550.14D
RSLV 02/22/2011 03/30/2011 07/20/2011
 
007 ( 19) DEFECTIVE WIRING IS IN USE
APARTMENT #2-NO RECEPTACLE PROVIDED FOR GAS STOVE
RSLV 02/22/2011 03/30/2011 07/20/2011